AVEVA™ System Platform, formerly Wonderware
Version 2020 R2 Readme

Last revision: 12/8/2020

This document contains important information about AVEVA System Platform 2020 R2.

Important: Support for 32-bit operating systems and 32-bit SQL Server versions has been discontinued. System Platform 2020 R2 is only compatible with 64-bit operating systems and SQL Server versions. If you have a 32-bit version of SQL Server, you must uninstall it before installing System Platform. System Platform will check that an installed SQL version is compatible prior to installation, and will display an error message if the installed SQL Server version is not compatible for any reason (not only for 32-bit versions). For information about moving from 32-bit to 64-bit SQL Server, refer to Issue 1249251 under Install/Uninstall and Galaxy Migration Issues. For general information about SQL Server requirements, see SQL Server Notes.

In This Document

Included in This Release

About This Release

Important Information for Highly Secured Environments (TLS 1.2 Exclusively)

How to Find the Latest Product Requirements and Compatibility Information

New Features in System Platform 2020 R2

Web Help Display and Video Playback

AVEVA OMI SDK

System Requirements and Guidelines

System Platform Installation

System Platform Upgrade and Migration

Licensing Information

Antivirus Software

Resolved Issues

Known Issues

Documentation

Included in This Release

Program Name

Version

AVEVA Application Server 2020 R2 including AVEVA OMI

20.1.000

AVEVA Communication Drivers Pack 2020 R2

7.2.0

AVEVA Enterprise License Manager

3.7.00000

AVEVA Enterprise License Server

3.7.00000

AVEVA Enterprise Licensing Platform

3.7.00000

AVEVA Historian, formerly Wonderware 2020 R2

20.1.000

AVEVA Historian Client 2020 R2

20.1.000

AVEVA InTouch HMI, formerly Wonderware 2020 R2

20.1.000

AVEVA InTouch Access Anywhere Server 2020 R2

20.1.000

AVEVA InTouch Access Anywhere Secure Gateway 2020 R2

20.1.000

Insight Publisher

4.2.000

Platform Common Services 4.5.1

4.5.20340.1

System Monitor Agent Install Manager 1.3

1.3.0

System Monitor Manager 1.3

1.3.0

About This Release

Changelog: System Platform 2020 R2

Change Description

Licensing enhancements

Ability to use AVEVA OMI layouts as content

Ability to add a background image to AVEVA OMI layouts

Support for Galaxy Style Libraries

Improved navigation node security

Support for Web Widgets in AVEVA OMI layout panes

New Graphic Repeater app

Alias names promoted to first class citizens

Security enhancements

Miscellaneous bug fixes

Incorporate InTouch HMI and Application Server hot fixes

Supported System Platform Versions for Product Upgrade

You can upgrade directly to AVEVA System Platform 2020 R2 from Wonderware System Platform 2014 R2 SP1 or newer.

All existing, installed products on a node must be upgraded to the same version. Therefore, when you upgrade a node to System Platform 2020 R2, all products on the node must be upgraded to version 2020 R2.

Important! System Platform does not support mixed Windows workgroup/domain environments. Although workgroups are supported, domain-based networking is recommended. However, you cannot use workgroup nodes within a domain environment.

Supported System Platform Versions for Migration

You can migrate user-created content (for example, .cab files, .aaPKG files, Historian databases, etc.,) to System Platform 2020 R2, as long as the content was created in one of the following product versions:

Server-based Licensing

AVEVA System Platform 2020 R2 continues to utilize the server-based licensing subsystem introduced in System Platform 2017. This new licensing subsystem provides centralized license management, and replaces the file-based licensing system that was used in prior releases. Licenses must be activated before use.

If you are upgrading from Wonderware System Platform 2014 R2 SP1 (with or without patches), you must first install and configure a license server node, and activate the licenses to ensure continuous plant operation. The license server is typically installed on the Galaxy Repository node, but you can use a dedicated license server. See the "License Installation and Activation" section of the System Platform Installation Guide (SP_Install_Guide.pdf), located at the root of the DVD.

Application Object Toolkit

Microsoft .NET Framework 4.8 is required for System Platform 2020 R2. When the System Platform installation process begins, it automatically checks the .NET version and installs the correct version if needed.

The Application Object Toolkit (AOT) is not included in the System Platform 2020 R2 release, but if you use AOT to build objects for Application Server, check that you have installed and configured the developer pack for .NET 4.8 when you create your AOT solution in Visual Studio.

Start Menu and Shortcut Changes

Some Start menu folders and some of the System Platform shortcuts they contain have been renamed. Commonly used applications, such as the Change Network Account utility, Configurator, and System Platform Management Console, are now located under the AVEVA Start menu folder. These were under the Wonderware Utilities folder prior to System Platform 2020.

Old Name

System Platform 2020/2020 R2 Name

Type

Wonderware Utilities

AVEVA

Folder

Wonderware Documentation

AVEVA Documentation

Folder

Wonderware Historian

AVEVA Historian

Folder

Wonderware InTouch

AVEVA InTouch

Folder

Wonderware System Platform

AVEVA System Platform

Folder

Sentinel System Monitor

AVEVA System Monitor

Folder

ArchestrA Service Bus Portal

Common Services Portal

Shortcut

AVEVA Enterprise License Manager

Enterprise License Manager

Shortcut

Sentinel Application

System Monitor Application

Shortcut

Readme Files for Other Products in this Release

To access individual product Readme files, insert the System Platform installation DVD and navigate to the applicable folder under the InstallFiles directory. Review the known and resolved issues contained in each Readme file for the component products updated for this release:

Product

Location on Installation DVD

Application Server 2020 R2

InstallFiles/CD-ApplicationServer/Readme.html

InTouch HMI 2020 R2

InstallFiles/CD-InTouch/Readme.html

Historian Server 2020 R2

InstallFiles/CD-Historian/Readme.html

Historian Client 2020 R2

InstallFiles/CD-HistorianClient/Readme.html

InTouch Access Anywhere 2020 R2

InstallFiles/CD-Server/Readme.html

Important Information for Highly Secured Environments (TLS 1.2 Exclusively)

Affected Systems

This information is applicable to a small subset of highly secured environments, in which operating systems and supporting networks have been configured to enable TLS 1.2 and where TLS 1.0 and 1.1 have been purposefully disabled. In these rare instances, some additional configuration is required to ensure that System Platform will work as expected.

System Platform 2020 R2 includes various measures to strengthen security, including the ability to leverage TLS (transport layer security) 1.2, provided that TLS 1.2 is enabled and configured in the host operating system.

In some cases, you may have to enable TLS 1.2 support by applying Microsoft updates and by making several manual edits to the system registry. The tasks of applying all Microsoft updates and editing the system registry must be completed before you install System Platform 2020 R2. These instructions also apply to any other software products that support TLS 1.2. Follow the instructions listed below.

If you are required to enable TLS 1.2 and disable TLS 1.0 and TLS 1.1:

  1. Before installing System Platform 2020 R2, make sure that your computer is up to date by downloading and installing all applicable Microsoft updates.
  2. If required by the updates, restart your computer.
  3. Edit the system registry (requires administrator permissions). For additional information about these registry changes, see the Microsoft document, Configuring security via the Windows Registry.

    The .REG file shown below sets registry keys to their safest values.

    Windows Registry Editor Version 5.00

    [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Microsoft\.NETFramework\v4.0.30319]

    "SystemDefaultTlsVersions"=dword:00000001

    "SchUseStrongCrypto"=dword:00000001

    [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\.NETFramework\v4.0.30319]

    "SystemDefaultTlsVersions"=dword:00000001

    "SchUseStrongCrypto"=dword:00000001

  4. Restart your computer to ensure that all changes take effect.
  5. Install System Platform 2020 R2.

How to Find the Latest Product Requirements and Compatibility Information

For important information about this product release, go to the AVEVA Global Customer Support (GCS) website. Information on the GCS website includes product requirements, compatibility, as well as downloads from previous releases. After you log in, you can filter search results by product name and the release/version.

New Features in System Platform 2020 R2

System Platform 2020 R2 includes the following new features, as well as miscellaneous bug fixes.

New Features in Application Server and AVEVA OMI 2020 R2

Alias Names

Alias Names are now first class citizens in the system.

Graphic Repeater App

The Graphic Repeater app allows a single graphic to be shown multiple times in an AVEVA OMI layout pane, with each occurrence using different values. Dynamic sorting of the graphic, based on the current run-time values, is supported.

Web Widgets

Web Widgets, previously supported only in InTouch HMI windows, are now supported in AVEVA layout panes.

Navigation Node Security

Navigation Node Security can now use roles.

Galaxy Style Libraries

Galaxy Style Libraries are supported and the Galaxy Style Library can be dynamically changed at runtime.

Support for Expressions in External Content Objects

External Content objects, which previously could use only static strings, now allow dynamic strings. These dynamic strings can be any combination of static strings, references, and complex expressions. The behavior of the dynamic content is determined at run time, and is the same as provided by the Industrial Graphic Editor.

Flex License Mode Configuration

Flex License mode configuration has been enhanced.

Layout Background Image

A background image can be set for an entire AVEVA OMI layout.

GR Access Toolkit

The GR Access Toolkit has been updated to support Flex licensing. The toolkit is available as a separate download from AVEVA Support website:
https://softwaresupport.aveva.com/

Linked Layouts

Layouts can be used as content and linked to templates and assets.

Licensing

The Galaxy Repository process periodically retries obtaining a license if it cannot obtain one, or if it loses an acquired license.

New Features in InTouch HMI 2020 R2

InTouch HMI 2020 R2 includes a number of new features, hot fixes, and provides support for the latest versions of Microsoft products. Refer to the GCS Technology Matrix for the list of supported Microsoft products. The following section summarizes the major features introduced in this release.

AVEVA Connect

Enhancements and improvements in security and performance to the integration with AVEVA Connect.

Web Widgets

This release introduces two new web widgets QR Code Scanner and Web Browser.

InTouch HMI as an OPC UA Server

InTouch HMI can now function as a secure OPC UA Server allowing OPC UA clients to connect to it.

Web Client

The following enhancements and improvements were made to the Web Client this release:

New Features in Historian 2020 R2

Declarative Engineering Unit Conversion

Support for UOM conversion during retrieval, new Engineering Units Catalog added to SMC.

Enhanced Excel add-in

Support for Excel custom functions, UOM conversion, periodic numeric retrieval supports event based time slicing.

AVEVA Historian Client Web (previously known as Historian Insight)

Support for UOM conversion, new alarm grid page.

Tag Extended Property Administration

SMC supports adding/editing/deleting tag extended properties.

Volume Shadow Copy Aware Backups

Support for Microsoft Windows Volume Shadow Copy Service (VSS), enabling consistent backups without shutting down the Historian.

High-Latency Network Support

Replication supports high-latency networks.

New Features in Historian Client 2020 R2

Trend supports UOM conversion

Web Help Display and Video Playback

Web Help - Browser-based User Assistance

Web help components have been delivered in this release. Web help opens in the default browser on your local computer. Help displayed in a browser allows more dynamic and searchable user assistance including standard web browser navigation and tutorial videos.

Typically, help content is installed on your local machine as part of the documentation library, and displays in your browser without requiring an Internet connection. When you install the Application Server IDE, a link to the AVEVA OMI Web Help is added to the Windows start menu. To open the help, use one of the following methods (depending on the editor/UI you are using):

Browser Requirements and Recommendations

Internet Explorer is recommended.

Browser Permissions for Displaying Web Help

Each browser and Windows operating system combination has its own security permissions. Using Internet Explorer as an example, you may see a dialog requesting that you "Allow blocked content" each time you invoke the web help. This dialog is triggered by the presence in the help system of JavaScript components that control internal navigation and topic display elements such as pop-up or in-place-expanding display blocks that contain text and graphical images. The text and image content is itself non-active.

You can accept each occurrence of this dialog, or you can set the following option in Internet Explorer, depending on your IT security requirements: In Internet Options, click the Advanced tab, then navigate to the Security section. Enable the "Allow active content to run in files on My Computer." Permissions and security settings will vary depending on your specific browser.

Playback of Tutorial Videos

The web help may contain a number of brief tutorial videos. To play these videos, you must have Microsoft Media Player installed on your local machine. In Windows Server operating systems, you must enable the "Desktop Experience" feature using Server Manager.

Internet Explorer (or IE-rendering in other browsers) may be required for viewing video content. If using a browser other than Internet Explorer without IE rendering enabled, videos may not be visible.

AVEVA OMI SDK

The AVEVA OMI Software Developer Kit (SDK) provides programmatic access to component APIs and namespaces. Using the methods and properties that these provide, you can build your own custom AVEVA OM applications. Users can then add these custom apps to their ViewApps, the same way that they can add the AVEVA OMI apps that are included with Application Server.

When you install the Application Server IDE, the AVEVA OMI SDK is automatically installed, including samples and libraries. A link to the AVEVA OMI SDK Web Help is added to the Windows start menu. The browser requirements and recommendations that apply to System Platform Web Help also apply to the SDK help.

System Requirements and Guidelines

Hardware Requirements Notes

 

 

 

Operating System, Firewall, .NET Framework, and Virtualization Notes

Minimum Operating System and Browser Requirements for System Platform 2020 R2

Windows Operating System Notes

.Net Notes

SQL Server Notes

Virtual Environment Notes

Firewall Notes

Operating System Notes: Common for AVEVA Products

Operating System Notes: InTouch HMI 2020 R2

Operating System Notes: Application Server

Operating System Notes: Historian Server

Operating System Notes: Historian Client

 

.NET Framework Requirements and Compatibility

Considerations for SQL Server

Considerations for SQL Server Express

Third-Party Application Prerequisites

 

 

 

Related Topics

AVEVA™ System Platform, formerly Wonderware Version 2020 R2 Readme

Included in This Release

About This Release

Important Information for Highly Secured Environments (TLS 1.2 Exclusively)

How to Find the Latest Product Requirements and Compatibility Information

New Features in System Platform 2020 R2

Web Help Display and Video Playback

AVEVA OMI SDK

System Platform Installation

System Platform Upgrade and Migration

Licensing Information

Antivirus Software

Resolved Issues

Known Issues

Documentation

System Sizing Guidelines

The following table provides guidelines for hardware configurations suitable for System Platform 2020 R2 software based on the size of the application. These guidelines are subject to the limitations of your Windows operating system, and if applicable, to the SQL Server edition (Express, Standard, or Enterprise). See the AVEVA GCS Technology Matrix for supported versions of Windows operating systems and SQL Server.

The following guidelines are provided for reference only. The system configuration required for your application will depend on multiple factors, including but not limited to the size and complexity of the application, and the features and components used.

Application

Level

Logical Processors

RAM

Free Disk Space

Network Speed

Application Server Nodes

Small Application
(1 - 25,000 I/O per Node)

Minimum

4

2 GB

100 GB

100 Mbps

Recommended

8

4 GB

200 GB

1 Gbps

Medium Application
(25,000 - 50,000 I/O per Node)

Minimum

8

8 GB

200 GB

1 Gbps

Recommended

16

12 GB

500 GB

1 Gbps

Large Application
(> 50,000 I/O per Node)

Minimum

16

16 GB

500 GB

1 Gbps

Recommended

32

24 GB

1 TB

Dual 1 Gbps

Galaxy Repository Nodes

Small Galaxy
(1 - 50,000 I/O per Node)

Minimum

4

2 GB

100 GB

100 Mbps

Recommended

8

4 GB

200 GB

1 Gbps

Medium Galaxy
(50,000 - 200,000 I/O per Node)

Minimum

8

8 GB

200 GB

1 Gbps

Recommended

16

12 GB

500 GB

1 Gbps

Large Galaxy
(> 200,000 I/O per Node)

Minimum

16

16 GB

500 GB

1 Gbps

Recommended

32

24 GB

1 TB

Dual 1 Gbps

Historian Server Nodes

Small Historian
(1 - 50,000 Historized Tags per Node)

Minimum

4

2 GB

100 GB

100 Mbps

Recommended

8

4 GB

200 GB

1 Gbps

Medium Historian
(50,000 - 200,000 Historized Tags per Node)

Minimum

8

8 GB

200 GB

1 Gbps

Recommended

16

12 GB

500 GB

1 Gbps

Large Historian
(> 200,000 Historized Tags per Node)

Minimum

16

16 GB

500 GB

1 Gbps

Recommended

32

24 GB

1 TB

Dual 1 Gbps

Thin Client Nodes

RDP clients, ITAA, mobile devices

Minimum

2

512 MB

N/A

100 Mbps

Recommended

4

2 GB

N/A

100 Mbps

Client Nodes

WindowViewer, ViewApp, Historian Client, Remote IDE

Minimum

4

1 GB

100 GB

100 Mbps

Recommended

8

4 GB

200 GB

1 Gbps

Remote-Desktop Server Nodes

Basic RDS, ITAA Server
Supports up to 15 concurrent remote sessions

Minimum

8

8 GB

200 GB

1 Gbps

Recommended

16

12 GB

500 GB

1 Gbps

Large RDS, ITAA Server
Supports up to 30 concurrent remote sessions

Minimum

16

16 GB

500 GB

1 Gbps

Recommended

32

24 GB

1 TB

Dual 1 Gbps

All-In-One Nodes

Small Application - All products on one node: 1,000 I/O max

Minimum

8

8 GB

200 GB

100 Mbps

Recommended

12

12 GB

500 GB

1 Gbps

Medium Application - All products on one node: 20,000 I/O max

Minimum

12

16 GB

500 GB

1 Gbps

Recommended

16

32 GB

1 TB

1 Gbps

Large Application - All products on one node: 100,000 I/O max

Minimum

20

32 GB

2 TB

1 Gbps

Recommended

24

64 GB

4 TB

1 Gbps

1) To calculate the number of logical processors: multiply the number of physical cores by the number of threads each core can run. A four core CPU that runs two threads per core provides eight logical processors. The terms "Hyper-Threading and "simultaneous multithreading" (SMT) are also used to describe logical processors.
2) SSD drives are highly recommended.
3) In redundant environments, increase CPU and RAM to maintain a maximum of 40% typical resource utilization.
4) For optimal performance of all-in-one nodes, a high clock speed (>2.8 GHz) is recommended.
5) For Application Server platform nodes, it is recommended that you deploy no more than two AppEngines per logical processor (typically one primary AppEngine and one backup).
6) For large applications on all-in-one nodes, dual XEON processors are recommended.

Supported and Recommended Node Hardware Types

Product

Server Node

Thin Client- Server Node

Client Node

Thin Client

All-In-One

Application Server

Galaxy Repository

Preferred

Supported

Supported

No

Supported

Application Engine

Preferred

Supported

Supported

No

Supported

IDE

Preferred

Supported

Supported

RDP

Supported

ViewApp Runtime

Supported

Supported

Preferred

ITAA/RDP

Supported

InTouch Standalone

WindowMaker (No Modern Apps)

Supported

Supported

Preferred

RDP

Supported

WindowMaker (with Modern Apps)

Preferred

Supported

Supported

RDP

Supported

WindowViewer / InTouch ViewApp (runtime only)

Supported

Supported

Preferred

ITAA/RDP

Supported

InTouch for System Platform

WindowMaker (with Managed Apps)

Preferred

Supported

Supported

RDP

Supported

WindowViewer / InTouch ViewApp (runtime only)

Supported

Supported

Preferred

ITAA/RDP

Supported

InTouch Access Anywhere

InTouch Access Anywhere Server

Supported

Preferred

No

No

Supported

InTouch Access Anywhere Client (HTML5 Browser)

Browser

Browser

Browser

Browser

Browser

InTouch Access Anywhere Secure Gateway

Supported

No

No

No

No

Historian

Historian Server

Preferred

Supported

Supported

No

Supported

AVEVA Insight (Historian Client)

Browser

Browser

Browser

Browser

Browser

Historian Client

Supported

Supported

Preferred

RDP

Supported

Support Components

OI Gateway

Preferred

Supported

Supported

No

Supported

AVEVA Enterprise Licensing - Server

Preferred

Supported

Supported

No

Supported

AVEVA Enterprise Licensing - Manager

Preferred

Supported

Supported

No

Supported

AVEVA Enterprise Licensing - Manager Client

Browser

Browser

Browser

Browser

Browser

Hardware Requirements Notes

Windows operating systems and SQL Server versions may impose hardware requirements that exceed the minimum requirements for System Platform 2020 R2. Refer to the following Microsoft Web sites for Windows and SQL Server hardware requirements.

Windows requirements

SQL Server requirements

AVEVA Historian Hardware Guidelines

For system sizing examples, see the System Platform Installation Guide (SP_Install_Guide.pdf).

Alternative Authentication Using Smart Cards

Operating System, Firewall, .NET Framework, and Virtualization Notes

Minimum Operating System and Browser Requirements for System Platform 2020 R2

The latest product information for each System Platform product is listed in the AVEVA Global Customer Support GCS Technology Matrix. Each link includes:

Minimum Required Operating System Version

The following table shows the minimum operating system for each product. See the GCS Technology Matrix for a list of all supported operating systems.

Product

Minimum Required Operating System Version

Client OS (x86 and x64)

Server OS (x64 only)

Application Server

Windows 8.1
Professional and Enterprise

Windows 10
Version 1803 (minimum)
Enterprise and IoT Enterprise

Windows Server 2012
Data Center (only)

Windows Server 2012 R2
Embedded (full image only), Standard, and Data Center

SAC versions of later Windows Server operating systems are not supported

InTouch

Historian

Important: Regardless of which operating system you are using, we recommend that you download and install the latest Microsoft updates to enhance security and ensure product compatibility.

Note: Only Windows Server versions licensed under Microsoft's long term servicing channel (LTSC) are supported. Versions of Windows Server licensed under the Semi-Annual Channel (SAC) do not include Desktop Experience, and therefore, are not supported. For example SAC versions 1709, 1903, and 2003 are not supported.

Supported Operating Systems at Time of Release

64-bit only

System Platform Product / Component

Windows 8.1
Pro/Enterprise

SAC Windows 10
Pro/Enterprise/IoT Enterprise

LTSC Windows 10
Enterprise/IoT Enterprise

LTSC Windows Server
See Windows Server Notes

Application Server 2020 R2

  • Galaxy Repository
  • AppEngine / Platform / Bootstrap
  • IDE (including remote)
  • AVEVA OMI ViewApp (run time)

Supported

1803
1809
1903
1909

2016
2019

2012
2012 R2 (including Embedded)
2016
2019 (Desktop Experience)

InTouch HMI 2020 R2

  • WindowMaker (no Modern apps)
  • WindowMaker (Modern apps)
  • WindowViewer (run time) / InTouchViewApp
  • InTouch Web Client (run time)

Supported

1803
1809
1903
1909

2016
2019

2012
2012 R2 (including Embedded)
2016
2019

InTouch for System Platform 2020 R2

  • WindowMaker (Managed Apps)
  • WindowViewer (run time) / InTouchViewApp

Supported

1803
1809
1903
1909

2016
2019

2012
2012 R2 (Embedded not supported)
2016
2019 (Desktop Experience)

Historian Server 2020 R2

Supported

1803
1809
1903
1909

2016
2019

2012
2012 R2 (including Embedded)
2016
2019 (Desktop Experience)

InTouch Access Anywhere Server 2020

  • ITAA Client (HTML5 browser)

    InTouch Access Anywhere Secure Gateway 2020

Supported

1803
1809
1903
1909

2016
2019

2012
2012 R2 (Embedded not supported)
2016
2019 (Desktop Experience)

Other System Platform 2020 R2 components / products

  • Historian Client 2020 R2
  • OI Gateway
  • System Management Server
  • AVEVA Licensing
  • System Monitor Agent / Manager

Supported

1803
1809
1903
1909

2016
2019

2012
2012 R2 (including Embedded)
2016
2019 (Desktop Experience)

SAC: Semi-Annual Channel (subscription)

LTSC: Long Term Servicing Channel

LTSC is the newer name for LTSB (Long Term Servicing Branch)

Windows Server Notes:

Important! Installing System Platform 2020 R2 on a computer used as a domain controller is not supported.
For more information, see the Microsoft Security Best Practices Checklist.

System Platform 2020 R2 Web Clients

The following web clients are included with System Platform 2020 R2:

The client programs listed above can be used with most common web browsers. Compatible browsers include:

Windows Operating System Notes

.Net Notes

SQL Server Notes

Upgrading SQL Server with AVEVA products installed is supported. See the AVEVA Global Customer Support GCS Technology Matrix for the complete list of supported SQL Server versions.

Only 64-bit versions of SQL Server are supported in this System Platform release. See Supported SQL Server Versions at Time of Release for more information.

If an error message about an unsupported SQL Server version is displayed while installing or upgrading to System Platform 2020 R2, check the following:

Supported SQL Server Versions at Time of Release

64-bit only

System Platform Product / Component

SQL Server Express SSMSE

SQL Server

Application Server 2020 R2

  • Galaxy Repository
  • AppEngine / Platform / Bootstrap
  • IDE (including remote)
  • AVEVA OMI ViewApp (run time)

 

2012 SP4

v11.0.7001.0 or higher

 

2014 SP3

v12.0.6024.0 or higher

 

2016 SP2

v13.0.5026.0 or higher

 

2017 Core

v14.0.1000.169 or higher

 

2019 Core

v15.0.2000.5 or higher

 

2012 Standard/Enterprise SP4

v11.0.7001.0 or higher

 

2014 Standard/Enterprise SP3

v12.0.6024.0 or higher

 

2016 Standard/Enterprise SP2

v13.0.5026.0 or higher

 

2017 Standard/Enterprise

v14.0.1000.169 or higher

 

2019 Standard/Enterprise

v15.0.2000.5 or higher

 

InTouch HMI 2020 R2

  • WindowMaker (no Modern apps)
  • WindowMaker (Modern apps)
  • WindowViewer (run time) / InTouchViewApp
  • InTouch Web Client (run time)

InTouch for System Platform 2020 R2

  • WindowMaker (Managed Apps)
  • WindowViewer (run time) / InTouchViewApp

Historian Server 2020 R2

System Monitor Manager

Default database is SQL Server Express 2017 Core

For information about which version of SQL Server you are running, see How to determine the version, edition, and update level of SQL Server and its components

Virtual Environment Notes

The following virtualization software and cloud-based virtual environments are supported for System Platform 2020 R2:

Firewall Notes

In order to establish communication with other components and services on the network, System Platform and ArchestrA Service Bus (ASB) services require certain network ports to be opened in the Windows Firewall. Typically, these ports are automatically opened for the Windows Firewall during installation. However, if the Windows Firewall service is disabled or not running at the time of installation, or if an alternative firewall is in use, you will need to manually open the appropriate network ports in the firewall. For more information about port configuration, see "Configuring ArchestrA Service TCP Ports" in the Application Server User Guide (filename: IDE.pdf).

Operating System Notes: Common for AVEVA Products

ActiveX Controls Behavior on Supported Windows Operating Systems

Due to the Data Execution Prevention (DEP) feature in Windows operating systems, any ActiveX control built with ATL version 7.1 or earlier will fail to host, or will behave unpredictably in InTouch, either in WindowMaker or WindowViewer.

The ActiveX controls and error message, along with solutions to resolve the behavior, are described in detail in TechNote 522, "Some ActiveX Controls NOT Supported in InTouch 2012 R2 (Version 10.6)". You can download this TechNote from the AVEVA Global Customer Support (GCS) website.

Configuring Remote Alarm Retrieval Queries

The process to configure remote alarm retrieval queries has changed for interactive applications such as InTouch HMI when running on currently-supported Windows and Windows Server operating systems.

When InTouch WindowViewer is started and generates alarms from an interactive Windows or Windows Server desktop session, an AlarmViewer control (running within InTouch HMI) on a remote node must be specially configured to query the alarms. The source alarms will not appear unless the AlarmViewer control's alarm query is configured.

This type of query only works for InTouch HMI as an alarm provider running in a Terminal Services session, not for InTouch HMI running in a console session.

To configure the AlarmViewer's alarm query

  1. After starting InTouch WindowViewer (alarm provider), open the SMC Logger and look for the most recent string generated by AlarmMgr. For example: "Registering AlarmMgr with SLSSVC as AlarmMgr 253.127.148.120". The indicated IP address will be unique to your alarm-providing node. Note the IP address for use in Step 2.
  2. In the Alarm Query tab of the AlarmViewer control on the remote computer, configure the alarm query as follows, substituting your nodename of the alarm providing InTouch HMI for "nodename" below and substituting your IP address noted in the previous step:

    \\nodename:ip_address\intouch!$system

    where nodename is the name of the node that is providing the InTouch alarm and ip_address is the IP address that you determined in step 1.

  3. Test to validate that the alarms generated from the alarm-providing node are shown accurately in the AlarmViewer control.
Terminal Services Behavior in Windows Server Operating Systems

Windows Server no longer supports the /console switch as a means of starting the remote desktop (RDP) client, also known as Session 0 or Terminal Server Console session. Session 0 is no longer an interactive session, and is reserved only for Windows services. Windows Server treats all remote connections as remote RDP sessions regardless of /console, /admin, or any other switches used to make the connection.

This impacts InTouch HMI functionality such as Alarm Manager that depends on the Terminal Server Console session. The impact to Application Server is minimal as most Application Server processes run as services. One impact to Application Server is to carry forward the restriction introduced with the Windows Vista operating system which permits only one alarm provider. While both Application Server and InTouch HMI can be configured as alarm providers, only one alarm provider can be configured at any one time.

Refer to the InTouch HMI Readme for further information about InTouch HMI applications running in the Terminal Server Console.

If you are running WindowViewer within a Terminal Server session and want to access alarms from WindowViewer in a client session, you must use the syntax \\terminalservernode:<IP address>\InTouch!$System to access the alarms, with a colon (:) after the node name. The IP address is that of the client computer connected to the session.

Operating System Notes: InTouch HMI 2020 R2

InTouch HMI with Supported Windows Operating Systems
InTouch HMI View Applications and DDE Support

NetDDE is not supported for InTouchView applications.

By design, an InTouchView application does not serve data to any other source, including InTouch HMI itself. When WindowViewer starts, it verifies if the application is an InTouchView application. When WindowViewer detects an InTouchView application, it does not register to become a DDE server. Industrial Graphics make use of the client layer when accessing InTouch tags, and appear as a third-party client trying to access WindowViewer as a data server. As a result, Industrial Graphics cannot communicate with InTouch tags when used with an InTouchView license.

In Industrial Graphics, InTouch:<tagname> is still a valid method of referring to an InTouch tag on a local node.

InTouch HMI Support for Windows User Account Control

System Platform 2020 R2 with InTouch HMI 2020 R2 supports User Account Control-enabled operations on run-time nodes.

Operating System Notes: Application Server

Using Application Server with Supported Windows Operating Systems

This section describes specific behaviors and restrictions when using the supported versions of Windows and Windows Server operating systems with Application Server.

Application Server and User Account Control Level

Application Server supports User Account Control-enabled operations. Starting the IDE requires elevated privileges.

Operating System Notes: Historian Server

Scenarios involving remote node communication fail if the Historian node is using the Windows 7, Windows 8, Windows Server 2008 R2, or Windows Server 2012 operating system.

For example:

  1. When you log in as a local administrator on a computer and try to add a remote Historian node (a second node with the Historian installed) using the network account from the Management Console, the status of the remote Historian node is not reflected correctly.
  2. Test the connection from a Historian node using the operating system to a remote tier-2 historian. The following error message is shown: "Test Connection to replication server () failed: cannot connect to Tier-1 replication service (error 0x80004005: Unspecified error)"
  3. Replication to the remote tier-2 historian fails.
  4. Although a remote IDAS service starts successfully, errors and warnings stating "Failed to get IDAS configuration version..." and "Unable to start data acquisition" are logged. This problem occurs if the ArchestrA user account is a local user. If the ArchestrA user account is a domain user, then this problem does not occur.

Workaround:

  1. Open a command prompt as Administrator and run the following command:

    reg add HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\system /v LocalAccountTokenFilterPolicy /t REG_DWORD /d 1 /f

    This sets LocalAccountTokenFilterPolicy registry entry value to 1. In doing so, an elevated token for the user is generated.

  2. Restart the system.

Operating System Notes: Historian Client

User Account Control can be enabled when the Historian Client application is running as non-administrator.

.NET Framework Requirements and Compatibility

IMPORTANT: System Platform 2020 R2 leverages the Microsoft .NET Framework 4.8 (or higher) version. Multiple versions of the .NET Framework can coexist, if other applications on the same machine have dependencies on other .NET versions.

All user-supplied .NET code that runs in the context of InTouch HMI and Application Server requires .NET Framework 4.8 or higher. Although the .NET Framework 4.8 is highly compatible with applications that are built with earlier .NET Framework versions, you may have to update your scripts.

In ArchestrA scripting, some .Net codes could fail if not using proper text encoding, and could cause a script to exit without completion. The UTF8Encoder is the default BinaryStream decoder in .Net 4.5 and later. To enable an ArchestrA script to decode ASCII XML data, for example, insert the following snippet:

BinaryReader streamReader = new BinaryReader(ms, new ASCIIEncoding());

To learn more about changes introduced in different versions of the .NET Framework, refer to the following Microsoft resources:

Considerations for SQL Server

SQL Server is required for Application Server, InTouch, and Historian Server. We recommend that you install and configure the supported SQL Server version before you begin the System Platform installation program. If you select SQL Server Express during System Platform installation, it will be installed automatically (applicable to small installations only).

The System Platform installer will install all prerequisites except the SQL Server requirement for installing the Historian Server. If you select the Historian Server for installation, and if the supported version of SQL Server is not already installed, you must exit the installation program, install the supported SQL Server version, then resume the installation.

Other considerations are:

Considerations for SQL Server Express

Additional SQL Server Notes for Application Server

Third-Party Application Prerequisites

For Historian Client:

System Platform Installation

For detailed installation instructions in English, see the AVEVA System Platform Installation Guide (SP_Install_Guide.pdf) or AVEVA System Platform Installation Help (SP_Install_Guide.chm). The Installation Guide pdf file is located in the root directory of the System Platform installation DVD. The Installation Help chm file is located in the InstallFiles directory of the installation DVD.

Before Installing System Platform

Important! Installing System Platform 2020 R2 on a computer used as a domain controller is not supported.
For more information, see the Microsoft Security Best Practices Checklist.

Some AVEVA products released prior to System Platform 2020 R2 must be installed BEFORE you install System Platform, if the product will be installed on the same node as System Platform. These are:

About the ArchestrA User Account

The ArchestrA user account is a user name and password combination that enables inter-node communication between all computers in an ArchestrA (System Platform) environment. You must specify the same user account on every node when you install the System Platform components for the first time on computers that communicate with each other.

WARNING! The ArchestrA user account is a Windows operating system account located on the local computer or on a domain. Do not delete this account with operating system account management tools. If you do, ArchestrA-enabled software may stop functioning properly.

After you install a System Platform component, you can use the Change Network Account utility to change or re-create the ArchestrA user account. The AVEVA Start menu contains a shortcut to the utility.

You must have Administrator privileges to use the Change Network Account utility. For more information, see the Change Network Account utility help, available from within the utility.

Note: If you re-create the user account using the Change Network Account utility, the Microsoft Windows security component on the computer can take several minutes to update this information on the Galaxy node. Until that occurs, the ArchestrA component may not function properly. Restarting the Galaxy node updates this information immediately.

System Monitor Installation and Configuration

We highly recommend the following System Monitor installation and configuration sequence. For more information and details, please see “Configuring the System Monitor Agent" and "Configuring the System Monitor Manager” in the System Platform Installation Guide (SP_Install_Guide.pdf).

  1. Install System Platform.
  2. Start the Configurator:
    1. Configure AVEVA Enterprise Licensing Platform > AVEVA Enterprise License Server
    2. Configure Common Platform > System Management Server
    3. On all machines with System Platform products, configure the AVEVA System Monitor > System Manager
    4. On the System Monitor Manager machine, configure the AVEVA System Monitor > Alert Email Server
    5. Configure the remaining product plug-ins.
    6. Restart your system.

Re-Connecting to System Management Server after Hardware Replacement or VM Restoration

If you connect a machine to the System Management Server and then later replace the machine due to hardware failure, or restore the VM to a state prior to that connection without first disconnecting the machine from the System Management Server, you will not be able to reconnect that same machine to the System Management Server.

Cause:

To protect the security of the system, the System Management Server uniquely identifies each machine that connects to it. If an intruder attempts to pretend to be that machine (spoofing) and re-registers with that machine’s name, the System Management Server will detect the mismatched identity and reject the suspected intruder’s registration.

Solution:

System Platform Upgrade and Migration

IMPORTANT! You can only upgrade to System Platform 2020 R2 if the prior version was installed on a 64-bit operating system.

You can upgrade directly to System Platform 2020 R2 from System Platform 2014 R2 SP1 or later, provided the prior version was installed on a 64-bit operating system.

Upgrading is defined as installing a newer version of the software when a previous version of the software exists. An upgrade is possible when the system requirements (operating system, SQL Server, .NET Framework) are met. The upgrade process will properly remove or uninstall the previous software version and install the new version. For versions older than the current and previous licensed versions, only the latest service pack or patch versions are tested. For distributed systems, some products must be upgraded in a particular order. For more information, see upgrade information for each product in the System Platform Installation Guide.

The earliest versions of Windows that support System Platform 2020 R2 are:

See the GCS Technology Matrix for complete information about operating system that you can use with System Platform 2020 R2 products.

IMPORTANT! Back up any relevant application configuration files or databases before you start an upgrade or migration.

Licensing Information

Once installed, a link to the AVEVA Enterprise License Manager can be found in the \AVEVA folder on the Start menu.

It can also be accessed by pointing your browser to the following URL:

http://<nodename>/AELicenseManager

where <Nodename> is localhost or the name of the node where the AVEVA Enterprise License Manager is installed.

License Server

The AVEVA Enterprise License Server can be installed separately from the AVEVA Enterprise License Manager.

Running Both InTouch HMI and AVEVA OMI in a Session on an RDS Server

In System Platform 2020 R2, running both InTouch HMI and AVEVA OMI in a session on an RDS Server will attempt to acquire two (2) Supervisory Client Server (unlimited) licenses instead of one (1).

If you have purchased a Supervisory Client Server license (unlimited RDP sessions on a single server) and then run both InTouch HMI and AVEVA OMI simultaneously, there can be issues acquiring the server license due to differences in how the license is handled between the two. The order of startup will impact the results.

This behavior is seen in only a limited number of instances, only when you have purchased a Subscription license. If you do see this behavior, change the order of InTouch HMI and AVEVA OMI startup.

If this behavior continues, contact AVEVA Software Global Customer Support (GCS), describe the behavior, and request a temporary license, typically valid for 60-days.

AVEVA OMI and InTouch HMI ViewApp License Reservation Device Name for Client Devices, RDP Servers, and Users

License Reservation

Reserving a license for a specific device ensures a license will be available for that specific device whenever it is needed, regardless of the number of devices connected to the system. Keep in mind, each license can only be reserved to a single device, so if the device names are unknown ahead of time, it's better to not use reservations and instead allow the licenses to be acquired on a first-come, first-serve basis.

User-based License Reservation

In the AVEVA Enterprise License Manager license reservation page it is possible to mark a license to be reserved to a specific user. While the reservation page allows this particular configuration, it's important to know that neither AVEVA OMI nor InTouch HMI ViewApps support user-based license reservations. The end-result will be the inability for the software to acquire the license reserved. Therefore, only use device-based reservations for Supervisory Client licenses.

Device-based License Reservation

When reserving a Supervisory Client license for a specific device, the Device Name needs to be the name of the computer running the InTouch HMI/AVEVA OMI ViewApp. In the case where the ViewApp is running inside of a Remote Desktop Session, on an RDS (aka: Terminal Server), then the Device Name needs to follow this naming pattern:

<RDSHostName>-<RDPClientName>-<index>

where RDSHostName is the name of the Remote Desktop Server (aka: RDS or Terminal Server), and RDPClientName is the name of the PC running the RDP client software, and "index" is 1, unless there will be multiple RDP sessions from a single client machine, in which case the index should be incremented (starting at 1) for each reservation for that specific RDP client, up to the total number of RDP sessions from that specific RDP client.

Reservation Examples

Situation: A computer with a hostname of "ControlRoomA" runs AVEVA OMI

Device Name: "ControlRoomA"

Situation: A computer with a hostname of "ControlRoomB" running a single Remote Desktop Client (RDP), connecting to the Remote Desktop Server (aka: Terminal Server) with a hostname of "PrimaryRDS"

Device Name: "PrimaryRDS-ControlRoomB-1"

Situation: Two computers with hostnames "SupervisorPC1" and "LineMgrA", respectively, each running a single Remote Desktop Client (RDP) connecting to the Remote Desktop Server (aka: Terminal Server) with a hostname of "PrimaryRDS"

Device Names:

Situation: A computer with a hostname of "ExecutiveDesktop" running four (4) Remote Desktop Clients (RDPs), connecting to the Remote Desktop Server (aka: Terminal Server) with a hostname of "PrimaryRDS"

Device Names:

AVEVA Enterprise Licensing Support for High Availability (HA) and Disaster Recovery (DR) in Virtual Environments

Virtual Environments: License Servers are supported in virtual environments. However, under certain circumstances, such as transferring a license from one virtual environment to another, the License Server may interpret the transfer as an improper move and therefore go into grace period.

High Availability: License Servers in a High Availability virtual environment are supported in specific topologies. Basic redundancy topologies are described in the AVEVA Enterprise Licensing online help.

Disaster Recovery: License Servers in a Disaster Recovery virtual environment will go into a grace period during DR activities. This is because DR activities are similar to an improper move of licenses and will trigger a grace period.

To avoid a grace period trigger in a DR virtual environment, we recommend that you run the License Server outside the virtualized DR environment and use a redundant License Server configuration through the functionality built into the License Server software. Another option is to purchase Disaster Recovery licenses at a discounted rate and establish a backup License Server with these additional licenses.

In all environments, we recommend you install and run the AVEVA System Monitor to monitor licensing functionality and view alerts on issues such as a License Server going into grace period or licenses expiring.

Antivirus Software

Antivirus Software should be implemented as part of a defense-in-depth strategy to secure your Industrial Control Systems. TechNote TN2865, available from the AVEVA Global Customer Support (GCS) web site, lists important information about antivirus software. Enter your GCS credentials to access the Tech Note.

https://softwaresupportsp.aveva.com/#/okmimarticle/docid/tn2865

Resolved Issues

See the product-specific Readme files for resolved issues.

Known Issues

The following important known issues are listed by their assigned CR or reference number in ascending order. Additional known issues are documented in the product-specific Readme files.

ASB, PCS and MGC Issues

ASB: ArchestrA Service Bus

PCS: Platform Common Services

MGC: Multi-Galaxy Communication

Issue Number

Description

TFS 1278013

In certain multi-galaxy environments (MGC) running different versions of System Platform and using OS User Security, Verified Writes from InTouch to an attribute on another Galaxy node do not succeed. This occurs where one node is running System Platform 2014 R2 SP1, and a Verified Write is attempted from an InTouch window to an attribute on another node that is running System Platform 2020. Both nodes have InTouch and the GR installed. The following error message is logged: "Write attempt failed for the following reason: 'Security error: 8018'." However, Verified Writes from Object Viewer are successful.

Workaround: When performing a Verified Write from an InTouch window, enter the user name in the format ".\<UserName". Do not use the format "<LocalMachineName>\<UserName>".

TFS 1263702

When upgrading from a node with Platform Common Services (PCS) 4.3.3 installed, such as the case when upgrading from System Platform 2017 Update 3 SP1 or installing on a node with RMP 2017 Update 2, errors are logged while deploying the OPCUA service. However, the service is deployed successfully. The errors are similar to the following:

Application certificate does not have an application URI: CN=AZURE2019

Failed! UnifiedAutomation.UaBase.StatusException: Application certificate does not have an application URI: CN=AZURE2019
at UnifiedAutomation.UaBase.ApplicationInstanceBase.LoadApplicationCertificate (ApplicationDescription application, String hostName, Boolean silent)
at UnifiedAutomation.UaBase.ApplicationInstanceBase.CheckConfiguration(Boolean silent)
at UnifiedAutomation.UaBase.ApplicationInstance.Start(ServerBase server, WaitCallback callback, Object userData, Boolean silent)
at PCS.Provider.OpcUa.UaServerHostedService.StartApplication()
at PCS.Provider.OpcUa.UaServerHostedService.<ExecuteAsync>d__7.MoveNext()

Workaround:

  1. Upgrade all nodes and install and configure PCS 4.4 on each.
  2. On the node that will function as the OPC UA Server, select the "No System Management Server configured" option and finish configuration.
  3. Start the Configurator again (reboot if necessary), and configure the System Management Server option as applicable for your system.

TFS 1161407

With only run-time components of System Platform 2017 Update 3 or Update 3 SP1 already installed, the following error is encountered when installing InBatch 2014 R3SP1, Batch Management 2017, or RMP 2018 SP1: "Error 1603 A newer version of Archestra Service Bus Framework 4.2.2 is already installed."

Workaround:

  1. Install InBatch/Batch Management/RMP first and then install System Platform 2017 Update3 or Update3 SP1. You will be prompted to upgrade ASB Framework and Licensing,
  2. Once this is complete, rerun System Platform installation to add products and components.

Alternate workaround:

If you choose to install System Platform 2017 Update3 or 2017 Update3 SP1 first, then:

  • Select and install GR components (not just run-time components), and then install InBatch/Batch Management/RMP.

TFS 1111134 TFS 1121155

In some circumstances, when using the Configurator to configure the System Management Server, you may be prompted to enter your user credentials. This may happen if the logged-in user does not belong to the aaAdministrators or Administrators OS group. If you are a member of either of these groups, enter your user name as DomainName\UserName. The logged-in user should be a direct member of the aaAdministrators or Administrator group. Using the credentials for a user that belongs to nested groups is not supported. That is, you cannot use credentials that belong to a group that is part of aaAdministrators or Administrators.

If you are not a member of aaAdministrators or Administrators on the local machine, you can obtain configuration privileges for another OS group by editing the file appsettings.json, and adding the name of the OS group to the file. The full path for this file is:
C:\Program Files (x86)\AVEVA\Platform Common Services\Management Server\appsettings.json.

To add an OS group to the file, add the new OS group after "aaAdministrators."

"AppSettings": {

"AllowGroups:: [

"aaAdministrators",

"insert new group name here"

]

TFS 1116282

In a very small set of multi-galaxy (MGC) environments, communications between some System Platform subscribers and a system service they subscribe to may not be secure. In these circumstances, communications still occur, but may not be secure. If all the following elements exist in an MGC topology, communications may occur over an insecure channel:

  • Galaxies are installed across multiple domains.
  • Multi-Galaxy Communication (MGC) is used.
  • One of the following subscribers is on one domain and the MxDataProvider service to which it is subscribed is on another domain:
    • WindowViewer
    • Object Viewer
    • An AppEngine that has input extensions on another galaxy

Workaround:

To ensure that communications are always secure, update the config files as follows.

  1. Locate aaEngine.exe.config and view.exec.config in the ArchestrA\Framework\Bin directory.
  2. Add the following to the <runtime> section of each file:

    <AppContextSwitchOverrides value="Switch.System.IdentityModel.DisableMultipleDNSEntriesInSANCertificate=false" />

  3. Create the config file aaObjectViewer.exe.config in the ArchestrA\Framework\Bin directory.
  4. Add the following text to aaObjectViewer.exe.config:

    <configuration>

    <runtime>

    <AppContextSwitchOverrides value=
    "Switch.System.IdentityModel.DisableMultipleDNSEntriesInSANCertificate=false" />

    </runtime>

    </configuration>

     

CR L00141660

 

In a system with two GR nodes, attempting to connect from the IDE on one node to a Galaxy on the second GR node does not succeed, and the IDE shuts down.

Workaround: Pair the GR nodes before trying to connect to the Galaxy on the other node. See "Working with Multiple Galaxies > Setting Up a Multi-Galaxy Environment" in the Application Server User Guide for information about configuring multi-Galaxy pairing.

CR L00139918

 

Uninstalling Wonderware InBatch versions 10.2 or 11.0 installed on a System Platform 2014R2 SP1 system results in a failure to connect to ArchestrA Service Bus (ASB) services. If you uninstall either of these InBatch versions then cannot connect to ASB services, run a repair on System Platform 2014R2 SP1 using Windows' Add/Remove Programs utility.

CR L00133534

 

Undeploying a galaxy with Object Viewer active will cause Object Viewer to shut down with an informational message that requires acknowledgement (click OK) to complete the shutdown. In a multi-galaxy configuration, with Object Viewer open, undeploying a paired Galaxy, then redeploying the galaxy without properly shutting down Object Viewer, can cause ASB services to fail to reconnect to the redeployed galaxy. To avoid this condition, click OK to shut down Object Viewer before redeploying the galaxy.

CR L00123474

Writing from InTouch to a remote galaxy using indirect tags can fail for some of the remote references. Object Viewers on two different nodes may show different values for the same reference. You can avoid this issue by deactivating Advanced Communication Management in the IDE. Additionally, if you use the same indirect tag with scripting more than one time, you can modify your scripts to set the indirect tag's name property to an empty string after the loop completes. For example, in the following script snippet, you would add the line highlighted with bold text:

 

IF bRunScript  THEN

    FOR tagval = 1 TO 3
      indirect.Name = "Testtag" + Text(tagval, "0");
    
        IF indirect.Value > 4  THEN
                indirect.Value  = 0;
            ELSE
                indirect.Value  = indirect.Value  + 1;
                indirect.Value  = indirect.Value  + 1;
            ENDIF;      
    NEXT;
      indirect.Name = "";

ENDIF;

 

CR L00123462

 

In a multi-galaxy environment, you can pair galaxies by IP address rather than using a node name (computer machine name). Unpairing galaxies identified by IP address fails when NetBIOS and DNS solutions are unavailable. Where your galaxies are identified by IP address, you must create a temporary host file to map the IP addresses as hostnames for purposes of unpairing.

For example, Node1 and Node2 are identified by IP address and are paired. To unpair them, do the following:

  1. Navigate to the Hosts file on Node1. In Windows 7 and Windows 2008 R2 operating systems, the Hosts file typically can be found at C:\Windows\System32\Drivers\Etc\.
  2. Open the Hosts file in Notepad. In Windows 7 and Windows 2008 R2 systems, you should right click the Notepad executable, and click Run as Administrator, then open the Hosts file from inside Notepad.
    Alternatively, you can click Start, then click Run, then enter the following command in the text box:
    notepad c:\Windows\System32\Drivers\Etc\Hosts.
  3. Edit the Hosts file:
    1. Enter the IP address for Node2.
    2. On the same line as the IP address, provide a node (computer) name.
    3. Enter IP addresses and node (computer) names for each node identified by IP address to be unpaired.
  4. Save and close the Hosts file. You should now be able to unpair the galaxies.

     

Install/Uninstall and Galaxy Migration Issues

Issue Number

Description

TFS 1354470

If Intelligence 2017 Update 1 (or prior version) is installed on a machine that has System Platform 2020 R2 installed, the Configurator cannot open after the system restarts.

Workaround: Install Intelligence 2017 Update 1 (or prior version), then install System Platform 2020 R2.

  1. Install Intelligence 2017 Update 1 and configure it.
  2. Install System Platform 2020 R2. System Platform will upgrade shared components such as Licensing during the installation process.
  3. Run the Configurator for System Platform 2020 R2 and restart the system.
  4. Run the Intelligence 2017 Update 1 Repair module (setup.exe). This will upgrade the Intelligence Configurator.
  5. Configure Intelligence using the upgraded Configurator.

TFS 1249251

Upgrading to System Platform 2020 from a prior version does not succeed if the prior version used a 32-bit version of SQL Server. Support for 32-bit SQL Server has been discontinued for the System Platform 2020 release.

Workarounds: Two methods for upgrading System Platform and migrating galaxies are listed below. Use the first method if you will use SQL Server Express, included with System Platform. Use the second method if you will be installing a 64-bit full version of SQL Server in place of a 32-bit version.

Method 1 (install SQL Server Express as part of System Platform installation):

  1. Detach the galaxy databases through SQL Server Management Studio.
  2. Back up the database files by copying the Galaxy folder in the path:
    C:\Program Files (x86)\ArchestrA\Framework\FileRepository\
  3. Uninstall the 32-bit version of SQL Server Express.
  4. Launch the System Platform 2020 installation program (setup.exe), and allow it to install SQL Server Express 2017 (64-bit).
  5. Restore the Galaxy folder to the path:
    C:\Program Files (x86)\ArchestrA\Framework\FileRepository\
  6. Attach the previously detached Galaxy database files.
  7. Restart the aaGR and Watchdog services.
  8. Launch the IDE, then connect to the galaxy and migrate it.

    Galaxy migration should succeed without any issues.

Method 2 (install full version of SQL Server):

  1. Detach the galaxy databases through SQL Server Management Studio and make a backup.
  2. Uninstall the existing 32-bit version of SQL Server.
  3. Install a supported 64-bit version SQL Server.
  4. Attach the previously detached Galaxy database files.
  5. Launch the System Platform 2020 installation program (setup.exe) and allow it to upgrade your products.
  6. After upgrade is complete, launch the IDE, then connect to the galaxy and migrate it.

    Galaxy migration should succeed without any issues.

TFS 1233570

The aaGR service generates errors and warnings when migrating a Galaxy from System Platform 2014 R2SP1 to System Platform 2020. This issue is most noticeable on nodes with eight or more cores, although it can also occur on nodes with six or fewer cores.

TFS 1224058

When a galaxy with an ITMEViewApp object is migrated to System Platform 2020, an "ArchestrAObjectSupport" error message is logged.

Note: This issue has been corrected in AVEVA™ Edge 2020.

Workaround: You can avoid this issue by contacting AVEVA Customer Support for a patch compatible with your System Platform release. Before migrating your galaxy to System Platform 2020, import the ITMEViewApp Object patch.

If you have already migrated your galaxy to SP 2020 and are seeing an error message, import the ITMEViewApp Object included in the AVEVA™ Edge 2020 release.

TFS 1135229 TFS 1157116

If InBatch 2014 R3 or InBatch 2014 R3 SP1 is installed on the same node as System Platform 2017 or 2017 Update 1, upgrading to System Platform Update 3 SP1 may result in a compatibility issue that stops the IDE from working.

Workaround: Upgrade InBatch to version 2017 or later before upgrading to System Platform 2017 Update 3 SP1. InBatch 2017 and later versions are compatible with System Platform 2017 Update 3 SP1.

TFS 1120630

A Modify operation on InBatch 2017 fails when InBatch 2017 or earlier is installed before System Platform 2017 Update 3.

Workaround: Install System Platform 2017 Update 3 first, then install InBatch.

TFS 931629

If a System Platform component is removed through the Control Panel ("Install/Uninstall Programs" applet), rather than by running the System Platform installation program (Setup.exe), errors messages will be logged, exception messages such as "FileNotFound" will be displayed, and Application Server deployment will no longer be successful.

Workaround: Use the "Modify" workflow, as described in the System Platform Installation Guide (SP_Install_Guide.pdf).

  1. Insert the System Platform installation DVD and run Setup.exe.
  2. Select the "Modify" option.
  3. Select or clear the components you want to add or remove and click Next.
  4. When the Verify Change dialog appears, click Modify.
  5. Click Finish when the changes are complete.

TFS 804308

While installing System Platform 2017 on a remote node using an RDP session, you may lose your RDP connection if the Windows Firewall Service is stopped and Startup Type=Manual. If you are unable to reconnect, try the following:

  • If you have another form of Desktop access, such as physical access to the node or virtual access using VM hosting tools, you can use that access to confirm that the installation was successful. The last installation step will ask you to restart. When the node restarts, the RDP access should resume working normally.
  • If you do not have Desktop access, forcibly restart the node (data loss may occur), which will allow RDP to reconnect. Then, run the installation again.

TFS 796068

On a Galaxy Repository, uninstalling Application Server results in restoring the ArchestrA User credentials to the registry.

AVEVA OMI Issues

Issue Number

Description

TFS 1369154

Under certain circumstances, an instance derived from a template with an invalid reference will not show a warning during design time. This can occur if the following occurs:

  1. A symbol is added to the Graphic Toolbox with an undefined relative reference, for example, “Me.Attribute001,” where Attribute001 has not been created yet.
  2. The symbol is then added to a layout.
  3. The layout is linked to a UDO (User Defined Object) template. When the template is saved, no warning is displayed.
  4. When an asset is derived from the template, no warning is displayed for the instance either.

    Result: Although no warnings are issued during design time, when you create and then deploy a ViewApp with the linked layout, and show the linked layout in any screen, an error message will be displayed at run time (or in Preview Mode) that will allow you to troubleshoot and correct the error. The message will be similar to:

    Element ‘TEXT1’ in Symbol ‘UDO_001.S1’ has Configuration error: Invalid reference ‘Galaxy1:Me.Attribute001’ with owning object ‘UDO_001’ does not exist.

TFS 1295525

You may not be able to see a WYSYWYG preview of a ViewApp if all of the following are true:

  • The Galaxy contains more than one ViewApp derived templates configured with the same layout
  • Two or more of the ViewApps are open in ViewApp Editors within the same IDE.
  • The same layout is shown in the WYSYWYG area.

    In this case, only the initial ViewApp Editor will render the layout with WYSYWYG preview.

    Workarounds: When multiple ViewApps are using the same layout, you can either:

  • Edit one ViewApp at a time, or
  • To enable side-by-side editing of the ViewApps, use multiple IDE instances. Open a single ViewApp Editor in each IDE, and edit only ViewApp per IDE.

TFS 1292338

Checkboxes and other WCC elements, when linked to an invalid User Defined Object attribute, do not retain settings. For example, a checkbox configured as True will immediately revert to False.

Workaround: This works as designed, and no workaround is needed. Linking to an invalid reference should not show any value.

TFS 1290949

Changes to an Object Wizard containing a symbol during run time or while in preview mode do not hide the symbols associated with the Wizard.

TFS 1290461

When quickly associating multiple apps to a ViewApp, an app that displays a message, such as a licensing dialog while rendering its WYSIWYG preview) may cause the ViewApp and the IDE to become non-responsive.

Workaround: Shut down the IDE process and restart the IDE.

TFS 1290401

A ViewApp becomes non-responsive when the user attempts to login to the running ViewApp from the Login dialog box.

TFS 1289649

Certain characters cannot be entered when the Layout Script Editor is set to the International US keyboard. Instead of the typed character, the keyboard produces a space.

Workaround: When there is need to type one of the international accented dead keys (such as " ' ~ ^ : ), use an external text editor such as Notepad, and copy and paste the text into the script editor. Note that the Layout Script Editor supports all international characters.

TFS 1281954

A Layout Editor window that extends beyond a monitor screen onto another monitor screen still spans multiple screens, even after selecting the Maximize button. The Layout Editor window should resize to the full screen size of a monitor after selecting the Maximize button.

TFS 1257142

During run time, the top of a slide-in pane (pane 2) in a ViewApp appears to be misaligned with the pane it slides over (pane 1) when "Hide Row When Empty" is enabled for pane 1.

Workaround: This is a minor aesthetic issue and does not affect functionality. If necessary, disable the "Hide Row When Empty" option.

TFS 1195009

Users experience a 5 to 10 second delay when selecting any option from the Configure New Asset dialog box or attempting to close the dialog box.

TFS 1160616

If an admin user logs in, launches a ViewApp, and then logs off the system while leaving the ViewApp running, registry keys are unloaded in the profile of the user account. This results in continuous errors from CheckPointFileServer in the logger similar to: ""INVALID HRESULT LINE765 File CheckPointFile.cpp hResult 80003fa after logging off and logging on as different users (non-admin)."

Cause: This is a known Microsoft issue. This problem typically occurs after an administrator uses a service account to log in to the server for an interactive session, and then logs off. For example, an administrator may log in to a Web Front End (WFE) server by using the farm account, and then log off. This activity forces the registry keys to be unloaded in the profile of that account, and makes the keys unavailable for future use. Microsoft recommends using either of the following workarounds to resolve this issue. For more information, see:

"800703fa Illegal operation attempted on a registry key" error

A COM+ application may stop working on Windows Server 2008 when the identity user logs off

Workaround 1: Do not log in to the server for interactive sessions by using a service account.

Workaround 2: Disable the related Windows User Profile Service feature as follows:

  1. Open the Group Policy editor (Gpedit.msc) on the affected server.
  2. Open the User Profiles folder in the following path:

    Computer Configuration > Administrative Templates > System > User Profiles
  3. Locate the "Do not forcefully unload the user registry at user logoff" setting.
  4. Change the setting to Enabled.

CR L00150114

SR59513303: TheGetCPTimeStamp() scripting method, when used in an AVEVA OMI action or named script within a symbol, does not return the timestamp at run time. Instead, it returns characters for the timestamp format, such as "mm/dd/yyyy hh:mm:ss." No errors or warnings will appear in the logger. This is similar to issue 777504, listed below.

Workaround: Use the GetCPTimeStamp() method in an object script instead of a symbol script.

TFS 1100582

Switching languages during run time while using multi-content panes that use locale-specific scripting calls can sometimes result in errors in the logger.

Workaround: Restart the ViewApp after switching the run-time language. This action fully resolves the issue with no loss of functionality.

TFS 988079

If you upgrade or migrate from version 2017 or 2017 Update 1, and have an AVEVA OMI ViewApp that uses the ShowGraphic scripting method, modeless windows will behave differently at run time in this version of AVEVA OMI.

  • Old behavior: a modeless window called by ShowGraphic was displayed in an AVEVA OMI pane.
  • New behavior: a modeless window called by ShowGraphic is now be displayed in a modeless popup window. A new scripting method, ShowContent, has been added. Use ShowContent to load a graphic or layout into a pane. Use ShowGraphic to load a graphic into a modeless or modal popup window. Note that the modal windows called by ShowGraphic will continue to behave the same way as in previous releases (a modal popup window is displayed).

Missing NavTree

After upgrading or migrating an AVEVA OMI ViewApp from 2017 to 2017 Update 1, a warning message states that the NavTree entity could not be found. In 2017 Update 1, this navigation object has changed and is now called “NavTreeControl.”

Workaround 1: To replace the NavTree object in a ViewApp or Layout when upgrading to System Platform 2017 Update 1:

  1. Open the ViewApp or Layout that shows the warning.
  2. In the ViewApp or Layout editor, look in the Actions list for all references to “NavTree.” An icon showing “Content not available” will be displayed for these references.
  3. To see the entire action list for a ViewApp, toggle the Actions for Primary switch to show Actions for Home (does not apply to the Layout editor).
  4. Replace the NavTree object with the new NavTreeControl.
    1. Search for NavTreeControl under the Toolbox tab.
    2. Drag the NavTreeControl onto the pane to replace the NavTree.
  5. Confirm that you want to replace the content, then save the ViewApp or Layout and close the editor.
  6. Verify Layouts and ViewApps no longer show any warnings related to the NavTree.
  7. Deploy the ViewApp.

Workaround 2: To replace references to NavTree when importing packages from System Platform 2017:

  1. Launch the IDE and open the “Find” dialog.
  2. Search for “NavTree” using the default search settings.

    If the package file contains the obsolete NavTree object, it will be listed in the search results.

  3. Double-click the NavTree search result, which will select the NavTree object in the Graphic Toolbox.
  4. Delete the NavTree object from the Graphic Toolbox.
  5. Use Workaround 1 to replace the NavTree object with the new NavTreeControl object.

     

TFS 774717

When an AVEVA OMI application (View.exe) that uses one of the following web controls is run in 4K mode or on multiple 1080p monitors, under certain circumstances the application may stop responding:

  • InSightApp
  • MapApp
  • WWWebAppControls

Workaround: When running a ViewApp that uses a web control on a 4K monitor, set the monitor resolution to 2560 x1440 or less. When running the ViewApp on 1080p monitors, do not attempt to span multiple monitors.

TFS 777504

The GetCPQuality() scripting method is not supported in AVEVA OMI. If used in a ViewApp, it always returns quality = 0 (bad quality). This is similar to issue L00150114, listed above.

TFS 781006

If an invalid custom property is added to a symbol, no warning is logged in the System Management Console, even though no value is displayed for the custom property.

TFS 781620

The Height and Width properties of a group with text elements do not change in accordance with changes made to the label font size, and are not rendered correctly.

TFS 784470

Tooltip animations that contain multiple lines of text with line breaks may not display properly in deployed ViewApp.

TFS 784474

A tooltip may partially cover the element with which it is associated in the deployed ViewApp.

TFS 787192

When OSGroup security mode is used, the VerifiedWrite dialog is not displayed when you modify the value of a VerifiedWrite attribute from a combobox, if you first attempted to perform the VerifiedWrite without having the correct security credentials.

TFS 789857

When an element style animation is configured with both a fill color and a blink color, the blink animation and color remain when an element style override is applied that specifies only a fill color and has the blink check box deselected.

Workaround: Set the initial state without blink, then apply overrides as needed with blink enabled.

TFS 789958

On some high resolution tablet devices, such as the Surface Pro 4, object names in the System Platform IDE may have insufficient line spacing between items, which can make it harder to read object names.

TFS 794383

When a custom property is changed from public to private, the change does not have any affect, and the value of the private custom property is shown at run time (private values should not be shown). Similar situations occur when:

  • An override values for a custom property that is later made private. The override is also shown at run time.
  • An override is applied to a custom property, and later the custom property is locked (can no longer be overridden). When the ViewApp is redeployed, the override value is still shown.

Workaround: Manually validate the outermost symbol and then deploy the ViewApp.

Application Server Issues

Issue Number

Description

TFS 1352630

When IP addresses are used for galaxy pairing, pairing is successful. However an error dialog is displayed and an error message is logged. The error message is similar to: "Failed to get the Discovery Service information for the target Galaxy Repository 'x.x.x.x'. Please see the logger for more details."

Workaround: We recommended that you use the hostname of the node for galaxy pairing.

If you use the IP address instead, make sure the reverse DNS lookup zone is configured properly on the DNS server. If the reverse DNS lookup zone is not set up while pairing the galaxy with the IP address, galaxy pairing may be successful. However you may see the message described above. You may safely ignore the error message.

CR L00138837

AppEngine can crash due to calls made to API dlls even when using try/catch. This issue is specific to Nullable data types. The recommendation is to use wrapped API DLLs in Application Server scripting.

TFS 1297211

If an instance object with a Boolean attribute is configured with read/write I/O (and options for invert, buffer, reflect input and output, and output every scan are enabled), the instance is overwritten by its parent template at run time, if the attribute in the parent object is configured as an Integer.

TFS 1296015

In a client-server System Platform implementation where the client node is running a remote GR and run time features, the asb.Watchdog service may stop. As a result, MXData and Authentication warning messages appear in the logger.

Workaround: Insert the System Platform installation DVD and run setup.exe, then select the Repair option. For more information, see "Repairing an Installation" in the System Platform Installation Guide (SP_Install_Guide.pdf).

TFS 1295718

After an expression in a template is changed from locked to unlocked and adding an invalid expression to a script, a derived instance goes into a warning state when the template is checked in. Even after the object is validated, the warning remains. However, there is minimal user impact as the instance object expression does not change. The only effect is that the object is in a warning state.

Workaround: To resolve the warning state of the instance, open the template, lock the script text, and check in the template.

TFS 1292344

If the System Platform IDE is running and an ipconfig /release command is followed by an ipconfig/renew command on a remote client machine, the IDE goes into an invalid state where the IDE is responsive but objects cannot be edited.

TFS 1291740

After editing a parent template with child template and instance objects across multiple hierarchy levels, checking in the template takes longer than expected.

TFS 1290449

A legacy object with field attributes goes into an error state after importing a package file having field attributes and converting them using the Galaxy menu option, Convert Legacy UserDefined Object, even after the object has been validated.

TFS 1287616

After adding an attribute, script, or symbol to a template with about 2500 child instances, checking in the template can take more than a minute.

TFS 1287606

At run time, an overview symbol shows the LocalSymbolSetting override, even though the override setting visibility was changed to false in the Object Wizard settings. This occurs only when the visibility setting is changed to false and a local override is present.

TFS 1283400

An aaPKG file containing a large number of objects or symbols may take longer to export or import in System Platform 2020 as compared to System Platform 2017 Update 3.

TFS 1279394

In Application Server 2020, the MxDataprovider service may have a memory leak of about 2MB per day (based on 5000 updates/sec or about 360 million changes/day).

TFS 1258604

The System Platform IDE becomes non-responsive after attempting to edit a ViewApp associated with a layout containing more than 32 panes.

TFS 1249822

If the aaGR process is restarted while importing a Galaxy, the import process does not complete.

TFS 1173359

A Build operation using the Application Object Toolkit 2014 (AOT) with System Platform 2017 Update 3 SP1 does not succeed.

Workaround: Do the following before building the object:

  1. Install the 4.7.1 (or later version) .NET Developer Pack on the same system with Application Server and AOT.
  2. In Visual Studio, set the AOT Object Editor target Framework to 4.7.1 or later.

TFS 1157633  

As a result of security enhancements in System Platform 2017 Update 3 SP1, ArchestrA object scripts are unable to connect to SQL Server.

Workaround:

  1. Connect to SQL Server Management Studio.
  2. In Object Explorer, select Security > Logins.
  3. Select and right-click <NodeName>\aaAdministrators from the Logins list and open Properties.
  4. In the "Database role membership" window, add the following database roles:
    • db_datareader
    • db_datawriter
  5. Click OK.

TFS 933752

Starting the IDE can take up to a minute if the node on which it is running is not connected to the internet.

Root Cause: To enhance security and reliability, System Platform will validate certificates. Windows then performs a check to see if the certificate has been revoked. Without an internet connection, Windows waits until the timeout for this check has been reached before allowing the IDE to start.

Workaround 1 (preferred): This method changes the default timeout for the certificate check.

  1. Open the Local Security Policy settings (enter "Local Security Policy" in the Start Menu search bar).
  2. Select Public Key Policies.
  3. Under Object Type, right-click on Certificate Path Validation Settings.
  4. Select the Network Retrieval tab.
  5. Set the both "Default retrieval timeout settings" to 1 second, or to the value you prefer. Typically, both URL retrieval and path validation cumulative retrieval require only milliseconds to complete.
  6. Save the new settings and exit.

Workaround 2: This method disables checks for revoked certificates.

  1. From the Control Panel or Internet Explorer, open Internet Options.
  2. Select the Advanced tab and scroll down to Security.
  3. Uncheck the option, "Check for publisher's certificate revocation."
  4. Save the new settings and exit.

Workaround 3: This method installs the certificates that the operating system is attempting to validate onto the local machine. Once installed locally, the operating system will no longer need to access the network to retrieve them.

  1. Locate any DLL or EXE file from AVEVA Software, LLC.
  2. Right-click on the file and select Properties.
  3. Select the Digital Signature tab.
  4. Select the AVEVA certificate from the list.
  5. Select View Certificate.
  6. On the dialog that appears, select Install Certificate and follow the prompts to install the certificate on the local machine.
  7. Locate the file FlxCore.dll and repeat steps 2 through 6 for it. By default, this file is located in:
    C:\Program Files (x86)\Common Files\ArchestrA\Licensing Framework\License API2

    The certificate name is "Flexera Software LLC."

 

Map App / Mobile Access Issues

Issue Number

Description

TFS 797198

If the unfill color is set to a gradient in an Unfill animation with an animation fill style, and the fill style animation is changed, it changes the unfill color property.

TFS 797226

If the expression type is set to String in the truth table for fill color animation, the fill style does not change when the value changes.

InTouch HMI Issues

The following known issues are in addition to those documented in the InTouch HMI Readme.

Issue Number

Description

TFS 1351507

Language switching is not supported for the Carousel Widget in runtime.

TFS 1369183

A Carousel Widget containing the Web Browser Widget, QR Code Scanner Widget, Trend Client Control, Alarm Client Control or SQL Data Grid Control will not display correctly in WindowViewer, as default browser security options prevent cross-origin requests.

TFS 1372178

Carousel widgets in a managed application migrated from InTouch 2020 to InTouch 2020 R2, do not contain the latest properties.

Workaround: On migrating a Galaxy from InTouch 2020 to InTouch 2020 R2, run the IDE as an Administrator atleast once, to allow loading the latest InTouch 2020 R2 carousel widget properties.

TFS 1371799

When an InTouch 2020 application (.aapkg) is exported and imported to InTouch 2020 R2, then the default namespace for a tag reference within a Carousel widget is not resolved in runtime.

Workaround: Open the graphic containing the Carousel widget. Edit any property and save the graphic. The tag reference is resolved, and the graphic is displayed in runtime.

TFS 1374896

After a graphic/toolset is created, the letter case of the graphic name cannot be changed in WindowMaker. For example: INTOUCH cannot be changed to InTouch.

Workaround: Rename the graphic to a temporary name. Rename the graphic again with the correct letter case. For example: Rename INTOUCH to ChangeName and then rename to InTouch.

TFS 1374842

InTouch HMI does not launch when Insight Publisher is uninstalled from System Platform 2020 R2.

Workaround: It is recommended not to uninstall Insight Publisher. However if Insight Publisher must be uninstalled, add ‘C:\Program Files(x86)\CommonFiles\ArchestrA’ to the Path environment variable after uninstallation, to allow InTouch HMI to launch correctly.

TFS 1377672

Connecting many clients to a busy OPC UA server may cause various warnings and errors to be logged from the InTouch OPCUA Host process. Warning messages are for information purposes only and do not indicate any loss in functionality. Error message indicate that the operation was aborted.

Workaround: It is recommended that client connections to the server be planned and monitored, so not to burden the server and cause connection failures.

InTouch Access Anywhere Issues

The following known issue is in addition to those documented in the InTouch Access Anywhere Readme.

Issue Number

Description

TFS 1280717

InTouch Access Anywhere cannot be removed through the Modify workflow. An error message is displayed that states, "To install this product, please run Setup.exe. The setup will now exit."

Workaround: Select the Remove workflow, instead of Modify, from the Maintenance dialog. This successfully deletes InTouch Access Anywhere and its components.

Historian Issues

Issue Number

Description

TFS 1345774

Logger errors from during the galaxy migration can occur if the Historian Client Control was renamed.

Workaround: If a Historian Client Control in the galaxy was renamed, and if there are errors during migration related to the Historian Trend Client (aaTrendControl), resolve this error as follows:

  1. After migration, delete the renamed Historian Client Control. Note the name of this control as you will need it to rename the new control with the same name.
  2. Import the latest Historian Client Control aaPKG file from the following folder:
    C:\Program Files (x86)\ArchestrA\Framework\Bin
    File name: aaHistClientTrendControl.aaPKG
  3. Rename the imported client control with its original name (from step 1).

 

Note: If you have multiple Historian Client Controls in the galaxy and errors are being logged, and you want to retain only the original Historian Client Control, you can do this as follows:

  1. Delete the Historian Client Control with its original name (aaTrendControl).
  2. Rename one of the other Historian Client Controls to the original name (aaTrendControl).
  3. Delete the control you renamed in step 2. Note: This rename/delete process is required to maintain references that use the control.
  4. Repeat as many times as necessary until you have deleted the controls.
  5. Import the latest Historian Client Control aaPKG file from the following folder:
    C:\Program Files (x86)\ArchestrA\Framework\Bin
    File name: aaHistClientTrendControl.aaPKG

TFS 931966

When using silent install to upgrade Historian to System Platform 2017 Update 1 from a version that set a default password for SQL Server users, warning messages are logged that alert you to set new passwords for various system users after the Configurator runs. Your system will continue to operate normally without resetting the passwords, but changing the passwords will increase system security.

TFS 924302

When installing Historian along with any other component, and the other component requests a system restart, if you restart immediately after closing out the Configurator, a number of warnings may appear in the logger from the Historian services. This is caused by a timing issue.

The warning messages can be safely ignored because they do not affect the configuration of the Historian, and do not have any effect on the system during or after the system restart.

Licensing Issues

Issue Number

Description

TFS 1303484

If "Unlimited Engine" FLEX licensing is configured for an Application Server platform, and the System Platform IDE is closed and then reopened, the FLEX licensing configuration is lost.

TFS 1300491

Activating OI Gateway consumes a license even though OI Gateway does not require a license unless the MQTT component has been configured and is in use.

Workaround: Reserve a license for each Communications Driver (OI Server) that requires a license. No licenses will then be available because they are reserved to other Communications Drivers. When OI Gateway is activated but not using MQTT, no license will be consumed by OI Gateway. OI Gateway will run without interruption.

TFS 1241116

MES 2017/2017 R2 may not acquire a trial license when installed with System Platform 2020. This is due to a file path name change for the TrialLicensePool that is part of the System Platform 2020 release. This issue only occurs if you are using a trial license.

For both MES 2017 and MES 2017 R2, the file path for the TrialLicensePool folder is:
C:\ProgramData\Schneider Electric\Licensing\TrialLicensePool

For System Platform 2020, the file path for the TrialLicensePool folder is:
C:\ProgramData\AVEVA\Licensing\TrialLicensePool

Workarounds: Use one of the following workarounds.

  • If only the file path "C:\ProgramData\Schneider Electric\Licensing\TrialLicensePool" is on your system, change the name of the "Schneider Electric" folder in the file path to "AVEVA." No other change is needed.
  • If both file paths exist on your system, copy the trial license from "C:\ProgramData\Schneider Electric\Licensing\TrialLicensePool" to "C:\ProgramData\AVEVA\Licensing\TrialLicensePool." No other change is needed

    If the AVEVA License Manager is open while you are moving the license file or renaming the file path, you may see a series of error messages. However, these will clear once the trial license is acquired. You can avoid this by closing the License Manager prior to renaming or moving the file.

TFS 793643

If you have not set a default browser, and you install System Platform with AVEVA Enterprise licensing selected, clicking the AVEVA Enterprise License Manager shortcut does not open the License Manager in the browser as it should. Instead, the shortcut opens in Windows Explorer. From Windows Explorer, you cannot open License Manager (the OK button is inactive).

Workaround: Follow the instructions for your operating system to set the default browser, and then open the AVEVA Enterprise License Manager from the shortcut, or:

Open your browser and copy the shortcut link, http://localhost/AELicenseManager, directly into the browser's address bar.

TFS 779958

When the same license is acquired on both a local node and in an RDP session that originates from the same node, the License Manager may not show all the licenses that have been acquired. This occurs even though the licenses are counted properly on the license server. The license count that you see applies only to the node you are viewing. Thus, once you reach your maximum number of licenses, you will not be able to acquire additional licenses, even though the license manager may indicate that more licenses are available.

System Monitor Issues

The following known issues are in addition to those documented in the AVEVA System Monitor Readme.

Issue Number

Description

TFS 8186

Removing machines from the Monitored Machines list does not remove the respective platform from the Galaxy diagram.

Workaround: Contact AVEVA Customer Support for a stored procedure to remove the machine from MSSQL, thus removing it from the Galaxy diagram.

TFS 8185

Clicking the help link opens the User Guide in browser, but the guide is never loaded.

Workaround: Refer to the AVEVA System Monitor User Guide to view the PDF edition of the help.

TFS 7294

Following platform undeploy, the Runtime Data Provider shuts down. On redeploy of the platform, the Runtime Provider does not restart and resume monitoring until the Galaxy is rediscovered.

Workaround: Following redeploy of a platform, manually rediscover the Galaxy (in the Galaxy Diagram area). Alternatively, stop and restart the "Sentinel Agent Service."

TFS 7123

Domain User Groups can be added in the System Monitor Manager User configuration area successfully, but users of an added domain group cannot log in to the application.

TFS 7066

Manually specifying a proxy server in the Local Area Network (LAN) Settings configuration dialog results in the inability to access the System Monitor Manager.

Workaround: Use an automatic configuration script (provided by your IT department) to configure a proxy server.

TFS 6306

Email alerts cannot be sent through secured SMTP.

ArchestrA Alarm Control Issues

If you create a filter for a history block query that results in no matches, "Not Connected" appears in the status bar and a warning is logged to the ArchestrA Logger. The status bar should show "Connected" even though no matches are returned.

AVEVA Edge Co-Existence Issues

AVEVA Edge is not a component product of System Platform, but is sometimes installed with it.

Issue Number

Description

TFS 1342283

If you attempt to upgrade a computer to System Platform 2020 R2 from System Platform 2020, and AVEVA Edge 2020 is installed on the same computer, an error message may be displayed that warns of an incompatibility. This will occur during the upgrade if certain registry values are incorrect, and the upgrade installation will be blocked.

Workaround: Use regedit to enter the correct registry values.

Location: HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\ArchestrA\Framework

  1. Change the value of InstallPath to “C:\Program Files (x86)\ArchestrA\Framework\” (add the final backslash character)
  2. Change the value of TargetInstallPath to “C:\Program Files (x86)\ArchestrA\” (add “ArchestrA\”)

Citect SCADA Co-Existence Issues

We do not recommend installing System Platform 2020 R2 on the same the node where Citect SCADA is installed. To avoid issues, we recommend that you install System Platform and Citect SCADA on separate nodes.

Issue Number

Description

TFS 1377931

If System Platform 2020 R2 is installed on a machine that already has Citect SCADA 2018 R2 installed, you cannot browse Citect SCADA 2018 R2 tags from the System Platform IDE.

Workaround: Install Citect SCADA 2018 R2 and System Platform 2020 R2 on separate nodes.

Documentation

The System Platform documentation is available Adobe Acrobat .pdf files that are available from the following locations on the System Platform DVD:

InstallFiles\CD-ApplicationServer\UserDocs

InstallFiles\CD-Historian\UserDocs

InstallFiles\CD-HistorianClientUserDocs

InstallFiles\CD-Intouch\UserDocs

In addition, AVEVA OMI Help is installed as web help when Application Server is installed. The web help is contained in a zip file in the InstallFiles\CD-ApplicationServer\UserDocs folder on the System Platform DVD. After Application Server installation, it can be launched from the Start Menu (under "AVEVA Documentation"), or from the following URL:

<System Drive>:\Program Files (x86)\ArchestrA\Framework\Docs\1033\NGX\index.htm

AVEVA OMI Help can also be invoked from within the System Platform IDE by selecting an AVEVA OMI object, such as a layout, screen profile, or AVEVA OMI ViewApp, and pressing Ctrl + F1.

To view the PDF documentation, you must first download the latest version of Adobe Acrobat Reader DC from the Adobe Corporation web site: https://get2.adobe.com/reader/.

You can also access online Help systems from within the software.

Common Components and Utilities User Documentation

InTouch HMI Documentation

Application Server Documentation

Historian Server Documentation

Historian Client Documentation