About this ReadMe

This document contains important information about Wonderware® Intelligence 2017 (v3.0). Review this document for Product enhancements and new features, system requirements and compatibility, resolved issues and known issues in this version and changes, if any, to the Intelligence software documentation included on this CD.

Release Summary

With the release of Wonderware Intelligence 2017 (v3.0), the following list of new features and enhancements are introduced.

Limitations for this release(an update soon after this release will resolve some of the limitations below):

Related Topics

Wonderware Intelligence 2017 (v3.0) Readme

About this ReadMe

System Requirements and Product Compatibility

Licensing

Resolved Issues

Known Issues

Software Documentation

System Requirements and Product Compatibility

For important information about Wonderware Intelligence 2017 product release, go to the Schneider Electric Software Global Customer Support (GCS) web site. Information on the GCS web site includes product requirements, compatibility, system requirements to install the Wonderware Intelligence software. You need to have a valid credentials to access the site. You can search for the information by product name and the release/version.

Licensing

Wonderware Intelligence Licensing

This release of Wonderware Intelligence enforces licensing through the new Schneider Electric Licensing system for the Intelligence Runtime and Dashboard Server concurrent licensing services.

For more information regarding Licensing, see the Schneider Electric License Server Guide available at the following location in the system where Schneider Electric Licensing is installed: All Programs -> Schneider Electric -> Schneider Electric License Manager User Guide.

NOTE: Make sure that you have a new license to install the Wonderware Intelligence software. Licenses for prior versions of Wonderware Intelligence will not work for Wonderware Intelligence 2017 (v3.0) release.

Tableau Components Licensing

The Analytics Client (Tableau Desktop) and Dashboard Server (Tableau Server) versions shipped with Wonderware Intelligence are allowed to access data only from the Wonderware Intelligence data store and data sources used in the Intelligence model (Drill-down scenario for example). Using the Analytics Client outside of those boundaries is a violation of the license agreement.

The Wonderware Intelligence software enforces licensing for the Analytics Client through license keys provided by Wonderware, on your license certificate. When you first start the Analytics Client, a software activation window prompts you to enter the license key. The same applies for the Dashboard Server.

NOTE: If you already have permanent activation codes for Tableau software, the same activation codes can be used with Tableau 10.4 shipped with Intelligence 2017 as long as you have a valid Customer First subscription for Wonderware Intelligence.

Resolved Issues

This section describes the resolved issues.

Issue Number

Description

L00144870

Measure is not getting updated in the Intelligence database when a value within Modification Period gets updated in the Source database. The issue was due to the event start and end time that was not picking up correctly in some environment resulting in the value not getting updated.

L00144358 / L00144554

Measure backfill does not aggregate the Calculation field correctly after data have been inserted and updated using the modification period. This issue is happening on two data rows where the period field timestamp is exactly same.

L00144595 / L00144498

Foreign key for Dimension is updated as 0 in the Measure table as the Dimension's Time Reference field value was stored in UTC in the data source which resulted in exclusion of or mark the dimension as obsolete.

L00142721

The TDD is not getting updated properly when an incremental update is enabled. As a result of this, data displays a double value in the data store. The issue is happening at the reprocessing stage, where the TDD - Process Order end time is changed and the reprocessing is not being triggered on the same.

L00142876

Ghost record with a wrong Measure period in the Measure table. The issue is resolved by fixing the UTC date-time conversion in the Intelligence Runtime.

L00141808 / L00141671 / L00143098

[[RequestedStartTime]] and [[RequestedEndTime]] filter is not calculating daylight saving time resulting in wrong Measure calculation.

L00144505 / L00144385

"Invalid value for wwTimeZone" error appears when using [[RequestedStartTime]] and [[RequestedEndTime]] filter in Japanese OS and French OS.

L00142331 / L00143085

TDDs Measure Reprocess issue resulting in loss of data. This is because of getting the start time for Measure with TDD/ContextLink. The measure refresh start time was set to last context date. This is a problem when the last context date falls into the last update period.

L00144651

In the Wonderware Intelligence Dashboard Licensing, the following error appears: " User doesn't exists in Tableau Server 'username' even when the User is already present. This issue happens when you have a user more than 100 users and the requested user is not listed in the first 100 users.

L00144793

When you run the Configurator for Concurrent Licensing, it does not allow you to use HTTPS Mode. This issue is resolved and the concurrent licensing related components now supports SSL.

Known Issues

The following table lists the known issues, listed by their change request number.

Issue Number

Description

L00108588

Measure records will get a valid context reference only when both the dimension key field's data type and measure source field's data type in the measure relation are the same. If they are not of the same data type, then 0 (meaning no matching record found) is assigned as the context reference for the measure record. This issue mainly occurs when you are using any numeric data type as a key dimension field.

L00136275

If you connect to an incorrect Wonderware Historian in the Data Source and then try to connect to the correct Wonderware Historian, the logger continuously logs warning messages that it is still unable to connect to the incorrect Historian.

Workaround: You must restart the Wonderware Intelligence Data Adapter service to stop the warning messages in the SMC logger.

L00136325

If a measure is undeployed while it is busy processing calculation, the following errors/warnings will be returned in the SMC logger: "ExecuteMeasureBackfill() failed unexpectedly. Retry measure backfill Measure [name of measure]." You can ignore these messages.

Software Documentation

The Wonderware Intelligence software documentation set includes the following:

The Wonderware Intelligence product library consists of a set of Portable Document Files (PDF) located in the UserDocs folder of the Wonderware Intelligence software installation media. You need Adobe Reader installed on your computer to view the Wonderware Intelligence software documentation. You can download the latest version of Adobe Reader from the Adobe Corporation web site:

http://www.adobe.com/products/reader.html

After installing Adobe Reader, double-click on a PDF file to view the book with Adobe Reader. You can also open a book with the Adobe Reader Open command from the File menu.

The Wonderware Intelligence software installation instructions are located in the root folder of the Wonderware Intelligence software installation media as an online Help file. You can view these instructions by clicking Help as you start the Wonderware Intelligence software installation procedure.

Related Topics

Wonderware Intelligence 2017 (v3.0) Readme

About this ReadMe

Release Summary

System Requirements and Product Compatibility

Licensing

Resolved Issues

Known Issues

Avantis  |   Industry Software Suites   |  OASyS  |   SimSci  |   SimSuite  |   Skelta  |   Wonderware

Copyright © 2017 Schneider Electric Software, LLC.  |  Contact Us