Last revision: 5/11/2023
This document contains important information about AVEVA Batch Management 2023 (v13.0). Review this document for known issues and changes to the AVEVA Batch Management software and documentation included on this CD.
NOTE: Readme files from previous releases of Wonderware InBatch software are posted to the AVEVA Knowledge & Support Center.
AVEVA Batch Management 2023 (v13.0) offers the following new features and enhancements:
Support has been added to whitelist the Operation Stations from where portal can be accessed.
Support has been added for Shared Components of System Platform 2023.
This section describes the hardware, software, and operating system required to install the AVEVA Batch Management software.
Hardware Requirements
Minimum Hardware Requirements
The following hardware is recommended to support AVEVA Batch Management:
Hardware Requirement
|
Client |
Server |
|||
---|---|---|---|---|---|
Small View Application |
Large View Application |
Small View Application |
Medium View Application |
Large View Application |
|
Processor |
1.8 gigahertz (GHz) |
1.8 gigahertz (GHz) |
2.8 gigahertz (GHz) |
2.8 gigahertz (GHz) |
2.8 gigahertz (GHz) |
Processor Cores |
2 (Minimum) 4 (Recommended) |
4 (Minimum) 8 (Recommended) |
2 (Minimum) 4 (Recommended) |
4 (Minimum) 8 (Recommended) |
8 (Minimum) 16 (Recommended) |
RAM |
1 GB (Minimum) 4 GB (Recommended) |
4 GB (Minimum) 16 GB (Recommended) |
2 GB (Minimum) 4 GB (Recommended) |
8 GB (Minimum) 12 GB (Recommended) |
16 GB (Minimum) 24 GB (Recommended) |
Hard Disk |
100 GB (Minimum) 200 GB (Recommended) |
200 GB (Minimum) 500 GB (Recommended) |
100 GB (Minimum) 200 GB (Recommended) |
200 GB (Minimum) 500 GB (Recommended) |
500 GB (Minimum) 1000 GB (Recommended) |
Video Adapter / Monitor Capability (Resolution) |
1024 x 768 (Minimum) 1920x1080 (Recommended) |
1024 x 768 (Minimum) 1920x1080 (Recommended) |
1024 x 768 (Minimum) 1920x1080 (Recommended) |
1024 x 768 (Minimum) 1920x1080 (Recommended) |
1024 x 768 (Minimum) 1920x1080 (Recommended) |
Network Speed |
100 Mbps (Minimum) 1 Gbps (Recommended) |
100 Mbps (Minimum) 1 Gbps (Recommended) |
100 Mbps (Minimum) 1 Gbps (Recommended) |
1 Gbps |
1 Gbps (Minimum) Dual 1 Gbps (Recommended) |
Input Devices |
|
Hardware Requirements - Operating System
See your specific Microsoft operating system hardware requirements for details.
Operating System Requirements
The following table lists the operating system, .NET Framework, and virtualization requirements for AVEVA Batch Management 2023.
Operating System
|
Client Windows OS (64-bit) |
Server Windows OS |
.NET Framework
|
Virtualization |
|
|
|
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
10 (Semi-Annual Channel) Pro, Enterprise, and IoT Enterprise 20H2, 21H1, 21H2
|
10 (Long Term Servicing Channel) Enterprise, IoT Enterprise 2019 (1809), 2021 (21H2)
|
11 (Semi-Annual Channel) Pro, Enterprise, and IoT Enterprise 21H2, 22H2 |
2016 (Long Term Servicing Channel) Standard, Data Center, IoT |
2019 (Long Term Servicing Channel) Standard, Data Center, IoT, Essentials |
2022 (Long Term Servicing Channel) Standard, Data Center |
4.8 |
5.0 |
6.0 |
7.0 |
Hyper-V shipped with supported version of Windows (Includes Gen1 and Gen2 VMs) |
VMWare VSphere 7.0.2 and newer (including HA/DR) |
VMWare Clients (including Horizon - App Virtualization) |
Cloud Virtualization - Azure |
VMWare Workstation 12.5.9 (Only) and 16.2.2 and newer |
Stratus HA/DR and FT based solutions (zTC Edge 110i) |
Nutanix (AHV version 20201105.2030, Nutanix AOS version - 5.20.8.1 LTS) |
VMWare vMotion v7 |
|
AVEVA Batch Management Server
|
Y |
Y |
Y |
Y |
Y |
Y
|
Y |
C |
C |
C |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
AVEVA Batch Management Clients
|
Y |
Y |
Y |
Y |
Y |
Y
|
Y |
C |
C |
C |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
AVEVA Batch Management History Server
|
Y |
Y |
Y |
Y |
Y |
Y
|
Y |
C |
C |
C |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
AVEVA Batch Management Reporting Content
|
Y |
Y |
Y |
Y |
Y |
Y
|
Y |
C |
C |
C |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Supported
|
Y |
Not Supported |
N |
Coexist. |
C |
Notes:
- For software requirements for the "AVEVA Batch Management Components for System Platform IDE" feature, see the software requirements for Application Server.
- For software requirements for the "AVEVA Batch Management Reporting Content" feature, see the software requirements for Microsoft SQL Server.
- If a supported version of the Microsoft .NET Framework is not installed, the AVEVA Batch Management installation automatically installs it.
Browser Requirements
Application Name |
Supported Version |
---|---|
Microsoft Edge |
Non-Chromium and Older Chromium 97.0.1072.76 and newer* |
Google Chrome |
Version 98.0.4758.80 and newer* |
Firefox |
Version 102.11 ESR and newer* |
Safari |
Version 15.2 and newer* (Mac and iOS only) (Not Windows) |
Opera |
Version 83.0.4254.16 and newer* |
* Unless later versions of browsers deprecate the user interfaces used by AVEVA Batch Management Reporting System.
Microsoft SQL Server Requirements
The following table lists the Microsoft SQL Server requirements.
|
SQL 2016 Express (SSME), Standard, Enterprise |
SQL 2017 Express Core/Express with Adv Tools), Standard, Enterprise (+All Cumulative Updates) |
SQL 2019 Express Core/Express with Adv Tools), Standard, Enterprise (+All Cumulative Updates) |
SQL 2022 Standard, Enterprise (+All Cumulative Updates) |
---|---|---|---|---|
AVEVA Batch Management Server |
N/A |
N/A |
N/A |
N/A |
AVEVA Batch Management Clients |
N/A |
N/A |
N/A |
N/A |
AVEVA Batch Management History Server |
Y |
Y |
Y |
Y |
AVEVA Batch Management Reporting Content |
Y |
Y |
Y |
Y |
Supported
|
Y |
SQL Database is not required for AVEVA Batch Management Server and Clients |
N/A |
Additional Software Requirements
The following table lists the additional typical software requirements for each AVEVA Batch Management station type when the AVEVA Batch Management software is used with System Platform (SP):
Additional Software Requirements |
AVEVA Batch Management Station Type |
|||||
---|---|---|---|---|---|---|
Server |
Run-time Client |
Development Client |
History Server |
Reporting Content |
Redundant System |
|
Application Server bootstrap and IDE |
Yes* |
- |
Yes |
- |
- |
Yes* |
InTouch |
- |
Yes |
- |
- |
- |
- |
*Application Server IDE is required only during Development for GRAccess, and not during Runtime. IDE is required for Tag Linker Editor for browsing the Galaxy by creating an Access Name. Application Server Bootstrap is required only for AVEVA Batch Management Server and Redundant Server during Runtime.
AVEVA Batch Management Firewall Exceptions List
AVEVA Batch Management requires certain network ports to be opened in the Windows Firewall to establish communication with other components and services on the network. Usually, this is automatically done during the installation and configuration process of AVEVA Batch Management. However, if the Windows firewall is not enabled at the time of installation or if an alternative firewall is in use during installation, you need to open the appropriate network ports in the firewall manually for proper functioning of AVEVA Batch Management. The following is a list of ports that must be added to the Windows Firewall exceptions list for AVEVA Batch Management:
For important information about this product release, go to the AVEVA Global Customer Support (GCS) website. Information on the GCS website includes product requirements, compatibility, as well as downloads from previous releases. After you log in, you can filter search results by product name and the release/version.
AVEVA Batch Management enforces licensing through AVEVA Enterprise License Manager.
Licensing Information
Once installed, a link to the AVEVA Enterprise License Manager can be found in the \AVEVA folder on the Start menu.
It can also be accessed by pointing your browser to the following URL:
http://<nodename>/AELicenseManager
where <Nodename> is localhost or the name of the node where the AVEVA Enterprise License Manager is installed.
License Server
The AVEVA Enterprise License Server can be installed separately from the AVEVA Enterprise License Manager.
Note: Prior to upgrading, confirm that your Hist Queue and Error Queue are empty. Because of changes to the AVEVA Batch Management History database, any data left in the Hist Queue or Error Queue will not be accessible in the upgraded version. Also, ensure that all batches have ended and that all warm restart files have been deleted.
For installation and upgrade instructions, see the AVEVA Batch Management Installation Guide and the Installation Issues section of this document.
Upgrading the software from the versions listed below only requires running the Setup.exe:
The process will upgrade all components as required.
The following is a list of important points that you must note during the upgrade process.
Any new .CSV files are also added to the following folder: "C:\Program Files\Wonderware\InBatch\Messages\English".
Note: If you are using the InBatch GUI Controls and upgrading from 10.2 or earlier, you may need to adjust some of your InTouch application layouts. Some of the controls have been increased in size to better accommodate larger values. Also, a new "Formula" column was added to several list controls.
This section describes resolved issues listed by their Defect ID (CR or IMS number).
Defect ID |
Description |
IMS 1313762 |
The value of some process parameters having double datatype is displayed as "-1.#QNAN00" in exported Recipe XML file. |
IMS 1425183 |
French OS installation has incoherent entries in the Batch History and generates Datetime errors in the errorq table. |
IMS 1775869 |
The method GetRecipeApprovals() creates Scriptruntime error: masterrecipeCheck_001.CheckRecipes: Type mismatch. (Exception from HRESULT: 0x80020005 (DISP_E_TYPEMISMATCH)) in WWLogger. |
IMS 1925607 |
After Migration, the Danish settings (delimiter ",") results in cryptic char in the Model Editor and values in RecipeEditor are empty. |
IMS 1929642 |
Security Clearance Request Popup shows strange/empty characters on popup elements (Action, UserID, Password, eccc..) during runtime. |
IMS 2177718 |
AVEVA InTouch OMI crashes when SFC App is displayed and logs the message "THREAD WARNING: SFC on different thread". |
IMS 2220116 |
AVEVA InTouch OMI application crashes due to multi-node connection failure from AVEVA InTouch OMI to AVEVA Batch Management Server by using .Net GUI controls. |
IMS 2264669 |
Engineering-Units are missing for phases parameters after importing Batch model into the galaxy. |
IMS 2431786 |
When the Batch Journal report is printed as a PDF, the error message appears as "Error: sub-report could not be shown". |
This section describes important known issues.
Installation Issues
2456284 |
AVEVA Batch Management application messages are not logged in SMC until the node is rebooted after installation. |
616969 |
Configuration of the History Server feature fails when you upgrade InBatch History Server to InBatch version 11.5.1 from versions prior to InBatch 11.0. Before proceeding with the upgrade, ensure that you delete all SQL Jobs related to Archive\Purge\Restore. Prior to InBatch 11.0 version, any SQL Agent jobs (Archive\Purge\Restore jobs) created in InBatch History Server may have been associated with BatchAdminUser, BatchReportAdmin, or BatchUser role. These user roles have been removed in 11.0 release. |
L00107356 |
Due to the large number of services running on IA Series platforms, the installation program should check the value of the SessionViewSize registry setting. It is likely that this registry value does not exist and will need to be created. If you ever notice that services unexpectedly fail to start, the value of this setting may be too small. Follow these steps:
|
L00127339 |
Machine names in redundant systems must be 12 characters or less. |
Other Issues
IMS 2353338 |
Unknown Opcode Internal Error dialog box is displayed in AVEVA InTouch 2023 when Batch Management ActiveX application switches to runtime. Workaround: Apply AVEVA System Platform 2023 P01 Patch.
|
|||||||||||||||||||||||||||||||||||
1055512 |
Batch Management web client Icons and images are distorted in Mozilla Firefox browsers. Workaround: Do the following settings in the Firefox browser:
|
|||||||||||||||||||||||||||||||||||
455938 |
When you access the InBatch Reports using Internet Explorer 11, the user interface fields of the Reports header are not displayed correctly. Note: This issue is reported only on a system with SQL Server 2012. Workaround: To resolve this issue, add the target site to Compatibility View Settings in Internet Explorer browser. |
|||||||||||||||||||||||||||||||||||
459424 |
Ensure that you adjust the InTouch application layouts to account for the new Formula column in the lists, if you are using GuiControl lists (ScheduleEdit.Schedule, BatchView.Batch, and BatchView.AllocationQueue). The width of other GUI Control lists may have also been increased to support better presentation of longer values. |
|||||||||||||||||||||||||||||||||||
614956 |
SSRS report execution (i.e. when you open the report and click 'View Report') displays a blank page in the Chrome browser.
Workaround: To resolve this error, do the following:
|
|||||||||||||||||||||||||||||||||||
L00077400 |
Editors are not opening on the AVEVA Batch Management development client.
Workaround:
|
|||||||||||||||||||||||||||||||||||
L00081552 |
Running Wonderware InBatch with IA components in a redundant configuration does not fail over when IADriver is shut down. The following table shows the redundancy status on master/backup nodes when IBMX, IBCli, and IADriver are stopped from the Runtime Services dialog box or when you end the process from the Task Manager.
|
|||||||||||||||||||||||||||||||||||
L00082612 |
Custom-created reports that are populated to the batch report directory are not available for configuration and scheduling. Use the following steps to configure and schedule the custom reports. For example, suppose a report named "Custom Batch Detail" is populated in the list.
|
|||||||||||||||||||||||||||||||||||
L00098867 |
When using the IBCli application, some I/O Servers or DAServers (including FS Gateway) may report an error about an "Unknown Watchdog" tag. This error is only reported when IBCli starts. However, the Watchdog tag still functions as expected. If you get the following errors from IBCli:
|
|||||||||||||||||||||||||||||||||||
L00125348 |
If you use the Import Utility in the preview mode, warning messages are not shown. This is observed when the utility imports a Wonderware InBatch ModelDB, in which any of the following have duplicate names (case sensitive): processes, transfers, segments, units, connections, or phases. However, warning messages are shown when you perform an actual import. |
|||||||||||||||||||||||||||||||||||
L00128201 |
When you run the cvtmaster for a second time, conversion fails.
Workaround:
|
|||||||||||||||||||||||||||||||||||
L00139186 |
Error and warning messages related to ReportQueueReader are logged in the SMC logger after you enable the Enhanced security mode using "aaConfigSQL" tool.
Workaround: Ensure that the ServiceDB user (configured to run the InBatch ReportQueueReader service) has access to printers and has the privilege to print. |
|||||||||||||||||||||||||||||||||||
1010526
|
Compatibility issues with Vijeo Citect 2016
|
|||||||||||||||||||||||||||||||||||
1102209 |
The 'History Admin' and the 'Report Web' pages display the following error: Unable to contact Batch Host to determine if security is enabled. Check Batch Host and restart browser.
This error is observed when you:
Workaround:
|
|||||||||||||||||||||||||||||||||||
157908 |
When the BatchHistory database and Batch Management reports are in distributed nodes, Batch Management reports execution is failing with the error "An error has occurred during report processing. (rsProcessingAborted). Query execution failed for dataset 'BatchDetailData'. (rsErrorExecutingCommand). Login failed for user 'NT Authority\Anonymous Logon' ".
Workaround: To overcome this error, do the following.
|
|||||||||||||||||||||||||||||||||||
IMS 1700890 |
After upgrading Batch Management to the latest version and when you import the Batch model in IDE, the following error gets displayed: "Error in creating toolsets or templates Method not found".
Workaround: To overcome this error, do the following.
|
To view these Help files, download and install the viewer component from Microsoft at http://support.microsoft.com/kb/917607.
The AVEVA Batch Management documentation set includes the following:
The AVEVA Batch Management product library consists of a set of Portable Document Files (PDF) located in the UserDocs folder of the AVEVA Batch Management installation CD. Install the Adobe Reader on your computer to view the AVEVA Batch Management documentation. You can download the latest version of the Adobe Reader from the Adobe Corporation web site:
www.adobe.com/products/acrobat/readstep2.htm
After installing the Adobe Reader, double-click a PDF file to view the book. Click the Open command on the File menu to open a book in the Adobe Reader.
The AVEVA Batch Management installation instructions are located in the root folder of the AVEVA Batch Management installation CD, as a .chm file. You can view these instructions by clicking the Help when you start the AVEVA Batch Management installation procedure.
The following messages are modified in the AVEVA Batch Management 2023 release.
Resource Name |
Message |
New/ |
SupervisorClient.csv |
||
ErrAddUserToModel |
Add user [{0}] to Batch Management security model and try again. |
Removed |
ErrAddUserToModelOpStation |
Add the user to Batch Management security model with authorization for Operator Station [{0}] and try again. |
New |