AVEVA Batch Management 2020 SP1 Readme

Last revision: 2/25/2022

This document contains important information about AVEVA Batch Management 2020 SP1 (v.12.5.1). Review this document for known issues and changes to the AVEVA Batch Management software and documentation included on this CD.

NOTE: Readme files from previous releases of Wonderware InBatch software are posted to the AVEVA Knowledge & Support Center.

In This Document

Release Summary

Minimum System Requirements

How to Find the Latest Product Requirements and Compatibility Information

Licensing

Installing AVEVA Batch Management 2020 SP1

Resolved Issues

Known Issues

Known Issues - Documentation

AVEVA Batch Management Documentation

Resource File

Release Summary

AVEVA Batch Management 2020 SP1 (v.12.5.1) offers the following new features and enhancements:

Minimum System Requirements

This section describes the hardware, software, and operating system required to install the AVEVA Batch Management software.

Hardware Requirements

Minimum Hardware Requirements

The following hardware is recommended to support AVEVA Batch Management:

Hardware Requirement

 

Client

Server

Small View Application

Large View Application

Small View Application

Medium View Application

Large View Application

Processor

1.8 gigahertz (GHz)

1.8 gigahertz (GHz)

2.8 gigahertz (GHz)

2.8 gigahertz (GHz)

2.8 gigahertz (GHz)

Processor Cores

2 (Minimum)

4 (Recommended)

4 (Minimum)

8 (Recommended)

2 (Minimum)

4 (Recommended)

4 (Minimum)

8 (Recommended)

8 (Minimum)

16 (Recommended)

RAM

1 GB (Minimum)

4 GB (Recommended)

4 GB (Minimum)

16 GB (Recommended)

2 GB (Minimum)

4 GB (Recommended)

8 GB (Minimum)

12 GB (Recommended)

16 GB (Minimum)

24 GB (Recommended)

Hard Disk

100 GB (Minimum)

200 GB (Recommended)

200 GB (Minimum)

500 GB (Recommended)

100 GB (Minimum)

200 GB (Recommended)

200 GB (Minimum)

500 GB (Recommended)

500 GB (Minimum)

1000 GB (Recommended)

Video Adapter / Monitor Capability

(Resolution)

1024 x 768 (Minimum)

1920x1080 (Recommended)

1024 x 768 (Minimum)

1920x1080 (Recommended)

1024 x 768 (Minimum)

1920x1080 (Recommended)

1024 x 768 (Minimum)

1920x1080 (Recommended)

1024 x 768 (Minimum)

1920x1080 (Recommended)

Network Speed

100 Mbps (Minimum)

1 Gbps (Recommended)

100 Mbps (Minimum)

1 Gbps (Recommended)

100 Mbps (Minimum)

1 Gbps (Recommended)

1 Gbps

1 Gbps (Minimum)

Dual 1 Gbps (Recommended)

Input Devices

  • CD-ROM or DVD-ROM drive for installation
  • Keyboard
  • Mouse or compatible pointing device

     

Hardware Requirements - Operating System

See your specific Microsoft operating system hardware requirements for details.

Operating System Requirements

The following table lists the operating system, .NET Framework, and virtualization requirements for AVEVA Batch Management 2020 SP1.

Operating System

 

Client

Windows OS

Server

Windows OS

.NET Framework

Virtualization

8.1

Professional,

Enterprise

(64-bit)

10

Pro, Enterprise, and IoT Enterprise 1909, 2004 Pro, 20H2 Pro, 21H1 (64-bit) Semi-Annual Channel (SAC)

10

Enterprise 2016 and IoT Enterprise 2016 LTSB

Enterprise 2019 and IoT Enterprise 2019 LTSC

Long-Term Servicing Channel (LTSC)

11

Pro, Enterprise

2012

Data Center

2012 R2

Standard,

Data Center,

Embedded (Full image)

(64-bit)

2016

Standard,

Data Center

(64-bit)

Long Term Servicing Channel (LTSC)

2019

Standard,

Data Center (Desktop Experience)

(64-bit)

Long Term Servicing Channel (LTSC)

IoT 2016 LTSB

IoT 2019 LTSC

2022 Standard, Data Center (64-bit)

3.5 SP1

4.7.2

4.8

Hyper-V shipped with supported version of Windows

(Includes Gen1 and Gen2 VMs)

VMWare VSphere 6.5 and newer

(including HA/DR)

VMWare Clients (including Horizon - App Virtualization)

Cloud Virtualization - Azure

VMWare Workstation 12.5.9 (Only) and 14.1.3 and newer

AVEVA Batch Management Server

 

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

C

Y

Y

Y

Y

Y

Y

Y

AVEVA Batch Management Clients

 

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

C

Y

Y

Y

Y

Y

Y

Y

AVEVA Batch Management History Server

 

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

C

Y

Y

Y

Y

Y

Y

Y

Batch Management Reporting Content

 

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

C

Y

Y

Y

Y

Y

Y

Y

Supported

 

Y

Not Supported

N

Coexist.

C

Notes:
- For software requirements for the "AVEVA Batch Management Components for ArchestrA IDE" feature, see the software requirements for Application Server.
- For software requirements for the "Batch Management Reporting Content" feature, see the software requirements for Microsoft SQL Server.
- If a supported version of the Microsoft .NET Framework is not installed, the AVEVA Batch Management installation automatically installs it.

Browser Requirements

Application Name

Supported Version

Microsoft Edge

Version 40.15063 and newer

Google Chrome

Version 72.0.3626 and newer*

Firefox

Version version 60.9 ESR and newer*

Safari

Version 11 and newer (Mac and iOS only) (Not Windows)

* Unless later versions of browsers deprecate the user interfaces used by AVEVA Batch Management Reporting System.

Microsoft SQL Server Requirements

The following table lists the Microsoft SQL Server requirements.

 

2012 Standard, Enterprise
SP4 (32/64-bit)

2014 Standard, Enterprise SP3 (32/64-bit)

2016 Standard, Enterprise
(SP2, SP2 + All Cumulative Updates)
(64-bit)

SQL 2017 Standard, Enterprise (+All Cumulative Updates)
(64-bit)

SQL 2019 Standard, Enterprise (+All Cumulative Updates)
(64-bit)

AVEVA Batch Management Server

N/A

N/A

N/A

N/A

N/A

AVEVA Batch Management Clients

N/A

N/A

N/A

N/A

N/A

AVEVA Batch Management History Server

Y

Y

Y

Y

Y

AVEVA Batch Management Reporting Content

Y

Y

Y

Y

Y

Supported

 

Y

SQL Database is not required for Batch Management Server and Clients

N/A

Additional Software Requirements

The following table lists the additional typical software requirements for each AVEVA Batch Management station type when the AVEVA Batch Management software is used with System Platform (SP):

Additional Software Requirements

AVEVA Batch Management Station Type

Server

Run-time Client

Development Client

History Server

Reporting Content

Redundant System

Application Server bootstrap and IDE

Yes*

-

Yes

-

-

Yes*

InTouch

-

Yes

-

-

-

-

*Application Server IDE is required only during Development for GRAccess, and not during Runtime. IDE is required for Tag Linker Editor for browsing the Galaxy by creating an Access Name. Application Server Bootstrap is required only for AVEVA Batch Management Server and Redundant Server during Runtime.

Batch Management Firewall Exceptions List

AVEVA Batch Management requires certain network ports to be opened in the Windows Firewall to establish communication with other components and services on the network. Usually, this is automatically done during the installation and configuration process of AVEVA Batch Management. However, if the Windows firewall is not enabled at the time of installation or if an alternative firewall is in use during installation, you need to open the appropriate network ports in the firewall manually for proper functioning of AVEVA Batch Management. The following is a list of ports that must be added to the Windows Firewall exceptions list for AVEVA Batch Management:

How to Find the Latest Product Requirements and Compatibility Information

For important information about this product release, go to the AVEVA Global Customer Support (GCS) website. Information on the GCS website includes product requirements, compatibility, as well as downloads from previous releases. After you log in, you can filter search results by product name and the release/version.

Licensing

AVEVA Batch Management enforces licensing through AVEVA Enterprise License Manager.

Licensing Information

Once installed, a link to the AVEVA Enterprise License Manager can be found in the \AVEVA folder on the Start menu.

It can also be accessed by pointing your browser to the following URL:

http://<nodename>/AELicenseManager

where <Nodename> is localhost or the name of the node where the AVEVA Enterprise License Manager is installed.

License Server

The AVEVA Enterprise License Server can be installed separately from the AVEVA Enterprise License Manager.

Installing AVEVA Batch Management 2020 SP1

Special Notes

Installing or Upgrading

For installation and upgrade instructions, see the AVEVA Batch Management Installation Guide and the Installation Issues section of this document.

Upgrading the software from the versions listed below only requires running the Setup.exe:

The process will upgrade all components as required.

The following is a list of important points that you must note during the upgrade process.

Resolved Issues

This section describes resolved issues listed by their Defect ID (CR or IMS number).

Defect ID

Description

CR - L00143794

When the product is upgraded from version 8.1 to version 11.5, the recipes become invalid in the later version because the Process instances are not available after the upgrade.

CR - L00158955

The user is allowed to print a report with unsaved recipe in the Recipe Editor which may lead to security vulnerabilities.

CR - L00159158

The Header is missing in each subsequent page of Procedure Reports generated from the Recipe Editor.

CR - L00159209

When the product is upgraded from version 10.1 to version 12.1, and the Batch History database is moved to another server, the user cannot configure the Batch History server when restoring the Batch History database (version 10.1) on the same node, where SQL Server is Named Instance.

CR - L00159650

After migration when the user re-issues a Batch Journal report on a Batch that took place before the migration, the information like User CheckBy, DoneBy in the Batch sequence does not appear.

CR - L00159657

Cannot configure the Reporting content when a SQL Named Instance is configured for the Batch History server.

CR - L00159972

When the product is upgraded from 10.1 to 12.1 some expressions do not evaluate. Transition gets triggered before assignment completes.

CR - L00159976

The electronic signatures (e-sigs) are missing while performing Batch operations when the user enables security for those batch operations.

IMS - 574128

Cannot add more than 7 digits after decimal for Input and Process Variables where decimal value range between >=-1 and <=1.

IMS - 944232

Batch Management .NET controls in InTouch OMI application are not working from Batch Management client node.

IMS - 946984

The Batch Manager stops or crashes. Also, the scheduled batch in Ready state starts unexpectedly without being set to Run state.

IMS - 1202153

The system crashes due to memory issues with BatchMngr.exe (v12.5).

IMS - 1398532

InBatch failover procedures are stuck with "hanging" clients because clients try to reconnect during the exit and shutdown requests.

IMS - 1465025

The Date field is missing in the Material Input Report.

IMS - 1407279

When upgrading the product from InBatch 2014 R2 to Batch Management 2020, switching the window in InTouch causes the view to crash due to Batch ocx while acquiring client license.

Known Issues

This section describes important known issues.

Installation Issues

1213460

When you install Batch Management on a computer where System Platform 2017 is already installed, ArchestrA IDE is not able to connect to the pre-existing Galaxy or create a new Galaxy.

Workaround: Do the following:

In the Registry Editor, under the "HKEY_LOCAL_MACHINE\SYSTEM\ControlSet001\Services\aaGR\" location, delete the Key "DependOnService" which has the value "ArchestrADataStore32".

Also, delete the Key "DependOnService" from the HKEY_LOCAL_MACHINE\SYSTEM\ControlSet002\Services\aaGR and HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\aaGR locations.

Restart the machine.

616969

Configuration of the History Server feature fails when you upgrade InBatch History Server to InBatch version 11.5.1 from versions prior to InBatch 11.0.

 

Before proceeding with the upgrade, ensure that you delete all SQL Jobs related to Archive\Purge\Restore. Prior to InBatch 11.0 version, any SQL Agent jobs (Archive\Purge\Restore jobs) created in InBatch History Server may have been associated with BatchAdminUser, BatchReportAdmin, or BatchUser role. These user roles have been removed in 11.0 release.

L00107356

Due to the large number of services running on IA Series platforms, the installation program should check the value of the SessionViewSize registry setting. It is likely that this registry value does not exist and will need to be created. If you ever notice that services unexpectedly fail to start, the value of this setting may be too small.

Follow these steps:

  1. Open the Registry Editor.
  2. Navigate down to [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Memory Management].

    If a registry value named 'SessionViewSize' exists, ensure that it is at least 30 (hex) or 48 (decimal).

    If it does not exist, create a new DWORD value named 'SessionViewSize' and set it to 30 (hex) or 48 (decimal).

L00127339

Machine names in redundant systems must be 12 characters or less.

Other Issues

1055512

Batch Management web client Icons and images are distorted in Mozilla Firefox browsers.

Workaround: Do the following settings in the Firefox browser:

  1. Open the Firefox browser.
  2. Navigate to Options > General.
  3. Under the Performance option, clear the Use recommended performance settings and Use hardware acceleration when available check boxes.
  4. Restart the browser.

     

455938

When you access the InBatch Reports using Internet Explorer 11, the user interface fields of the Reports header are not displayed correctly.

Note: This issue is reported only on a system with SQL Server 2012.

Workaround: To resolve this issue, add the target site to Compatibility View Settings in Internet Explorer browser.

459424

Ensure that you adjust the InTouch application layouts to account for the new Formula column in the lists, if you are using GuiControl lists (ScheduleEdit.Schedule, BatchView.Batch, and BatchView.AllocationQueue). The width of other GUI Control lists may have also been increased to support better presentation of longer values.

614956

SSRS report execution (i.e. when you open the report and click 'View Report') displays a blank page in the Chrome browser.

 

Workaround: To resolve this error, do the following:

  1. Browse to the Directory where reporting services is installed.

    For example: C:\Program Files\Microsoft SQL Server\MSRS11.MSSQLSERVER\Reporting Services\ReportServer.

  2. Open the file named reportserver.config.
  3. Insert the following line in the document:

    <Configuration >

    .......

    <HTMLViewerStyleSheet > SafariChromeFix </HTMLViewerStyleSheet>

    .......

    </Configuration >

  4. Save the file.
  5. Navigate to C:\Program Files\Microsoft SQL Server\MSRS11.MSSQLSERVER\Reporting Services\ReportServer\Styles directory.
  6. Make a copy of the file named SP_Full.css, and name the copy SafariChromeFix.css.
  7. Update the following lines to the top in the SafariChromeFix.css file:

    div { overflow: visible !important; }

  8. Save and close the file.

    All the existing reports on this instance of Reporting Services are displayed on all browsers including Chrome and Safari.

     

    Note: The reportserver.config may be overwritten with updates to reporting services. In such cases, add the <HTMLViewerStyleSheet > SafariChromeFix </HTMLViewerStyleSheet> tag into the config file every time.

     

L00077400

Editors are not opening on the Wonderware InBatch development client.

 

Workaround:

  1. Open a Microsoft Windows Explorer page.
  2. Navigate to C:\Programs\Wonderware\Wonderware InBatch\cfg\Config_A.
  3. Right-click the file vista.taf, and then select Delete.

     

L00081552

Running Wonderware InBatch with IA components in a redundant configuration does not fail over when IADriver is shut down.

The following table shows the redundancy status on master/backup nodes when IBMX, IBCli, and IADriver are stopped from the Runtime Services dialog box or when you end the process from the Task Manager.

 

 

IBMX

IBCli

IADriver

Action on the Master Node

Master Node Status

Backup Node Status

Master Node Status

Backup Node Status

Master Node Status

Backup Node Status

End process from Task Manager
(Correct Failover)

Master failed

Master with invalid backup

Master failed

Master with invalid backup

Master failed

Master with invalid backup

Stopped from Runtime Services
(Non-Failover)

Master with valid backup

Valid backup

Master with valid backup

Valid backup

Master with valid backup

Valid backup

 

 

L00082612

Custom-created reports that are populated to the batch report directory are not available for configuration and scheduling.

Use the following steps to configure and schedule the custom reports.

For example, suppose a report named "Custom Batch Detail" is populated in the list.

 

  1. Update the RptServicesConfig.xml file in the following location:

    <systemdrive>:\Inetpub\wwwroot\ReportWeb\ReportConfig

  2. Open the file RptServicesConfig.xml for editing.
  3. Add the following line under the <Reports> node:

    <Report Name="Custom Batch Detail" file="CustomBatchDetail.rdl" description="My Custom Report" />

  4. Save the file.

    Now the report named Custom Batch Detail is available for configuring and scheduling. Add a similar line for each custom report that is populated in the Execute Reports list.

     

L00098867

When using the IBCli application, some I/O Servers or DAServers (including FS Gateway) may report an error about an "Unknown Watchdog" tag. This error is only reported when IBCli starts. However, the Watchdog tag still functions as expected.

If you get the following errors from IBCli:

  • Too many ping timeouts (NOTE: only if you get this error repeatedly).
  • Failed to register 'Watchdog' ping tag - pinging is disabled.

    Do one of the following:

  • Try to upgrade to a newer I/O Server or DAServer version.
  • Create a tag called Watchdog in the I/O or DAServer. The tag can be of any data type.
  • Disable pinging using the IBCli Disable Ping option.

L00125348

If you use the Import Utility in the preview mode, warning messages are not shown. This is observed when the utility imports a Wonderware InBatch ModelDB, in which any of the following have duplicate names (case sensitive): processes, transfers, segments, units, connections, or phases. However, warning messages are shown when you perform an actual import.

L00128201

When you run the cvtmaster for a second time, conversion fails.

 

Workaround:

  1. Create a new folder and name it (E.g. Test). Ensure that the folder name is not Config_A.
  2. Copy the contents of the Config_A folder to the new folder.
  3. Run cvtmaster, directing it to the new folder.
  4. Copy the database from the new folder to the Config_A folder.

L00139186

Error and warning messages related to ReportQueueReader are logged in the SMC logger after you enable the Enhanced security mode using "aaConfigSQL" tool.

 

Workaround: Ensure that the ServiceDB user (configured to run the InBatch ReportQueueReader service) has access to printers and has the privilege to print.

1010526

 

Compatibility issues with Vijeo Citect 2016

 

  • In the Citect Design window, the application crashes when the 'InBatchGUIConfig' control is inserted prior to inserting the 'InBatchSFC' control on the same page.

    Workaround: The 'InBatchSFC' control must be inserted prior to the 'InBatchGUIConfig' control on the page/symbol.

  • Font size cannot be changed on any of the Batch ActiveX controls in Vijeo Citect.
  • An error message is displayed on the Control Area when you hold the InBatch Field ActiveX controls and drag them to a different location on page, during design time.
  • Tooltip does not get displayed on the Batch ActiveX controls at runtime.

1102209

 

The 'History Admin' and the 'Report Web' pages display the following error:

Unable to contact Batch Host to determine if security is enabled. Check Batch Host and restart browser.

 

This error is observed when you:

  1. Install and configure Batch Management Server on Node #1.
  2. Install and configure Batch Management History and Reports on Node #2.
  3. Launch Environment Display on Node #1.
  4. Launch History Admin page or Report Web page on Node #2.

 

Workaround:

  1. Launch Internet Explorer on Node #2.
  2. Under Tools, select Internet Options.

    The Internet Options dialog box appears.

  3. Click the Security tab and then select Trusted sites.
  4. Under Security level for this zone, click Custom level.

    The Security Settings – Local Intranet Zone dialog box appears.

  5. Under User Authentication > Logon, ensure that the Automatic logon with current user name and password option is selected.

     

1105212

Under the Usage Details tab in the Schneider Electric License Manager web page, the Device Name is displayed as:

  • “<<HOSTNAME>>.1” for the consumed Server license.
  • “<<HOSTNAME>>.2" for the Development/Runtime client license.

     

    Workaround:

    In the Schneider Electric License Manager web page, click Sync to synchronize the license server.

     

1105211

License refresh failed, and a valid client license could not be acquired from the license server. A warning message is logged in the SMC logger.

 

Workaround:

Apply the License Server Hot Fix CR L00150512.

 

157908

When the BatchHistory database and Batch Management reports are in distributed nodes, Batch Management reports execution is failing with the error "An error has occurred during report processing. (rsProcessingAborted). Query execution failed for dataset 'BatchDetailData'. (rsErrorExecutingCommand). Login failed for user 'NT Authority\Anonymous Logon' ".

 

Workaround:

To overcome this error, do the following.

  1. On the node where the Batch Management reports are configured, navigate to the SSRS Reports page.
  1. Open the Batch Management Reports folder and then click the ibReports data source.

    The ibReports data source Configuration Settings page appears.

  2. Select the Credentials stored securely in the report server option for Connect using.
  3. Provide the credentials of the user who has access to the ‘BatchHistory’ database.
  4. Click Test Connection to check if the provided user details have access.
  5. Once the connection succeeds, click Apply to save configuration settings.
  6. Execute the Batch Management reports from the Reports node and any other remote node where the Reports feature is not configured.
  7. Ensure that reports are executed successfully without any issues.

     

IMS 1700890

After upgrading Batch Management to the latest version and when you import the Batch model in IDE, the following error gets displayed:

"Error in creating toolsets or templates Method not found".

 

Workaround:

To overcome this error, do the following.

  1. Close IDE.
  2. Restart the' ArchestrA GalaxyRepository' service from the System Services window.
  3. Launch IDE and import the Batch Management Model.

     

Known Issues - Documentation

AVEVA Batch Management Documentation

The AVEVA Batch Management documentation set includes the following:

The AVEVA Batch Management product library consists of a set of Portable Document Files (PDF) located in the UserDocs folder of the AVEVA Batch Management installation CD. Install the Adobe Reader on your computer to view the AVEVA Batch Management documentation. You can download the latest version of the Adobe Reader from the Adobe Corporation web site:

www.adobe.com/products/acrobat/readstep2.htm

After installing the Adobe Reader, double-click a PDF file to view the book. Click the Open command on the File menu to open a book in the Adobe Reader.

The AVEVA Batch Management installation instructions are located in the root folder of the AVEVA Batch Management installation CD, as a .chm file. You can view these instructions by clicking the Help when you start the AVEVA Batch Management installation procedure.

Resource File

The following messages are modified in the AVEVA Batch Management 2020 SP1 release.

Resource Name

Message

New/
Modified

Notes

BatchDspl.csv

menu&Legal

&Legal

New

 

BatchSched.csv

menu&Legal

&Legal

New

 

BatchView.csv

menu&Legal

&Legal

New

 

EnvDspl.csv

menu&Legal

&Legal

New

 

EnvEdit.csv

menu&Legal

&Legal

New

 

IALink.csv

menu&Legal

&Legal

New

 

ImportExportUtil.csv

menu&Legal

&Legal

New

 

LogEdit.csv

menu&Legal

&Legal

New

 

MaterialEdit.csv

menu&Legal

&Legal

New

 

ModelEdit.csv

menu&Legal

&Legal

New

 

RecipeCompare.csv

menu&Legal

&Legal

New

 

RecipeEdit.csv

menu&Legal

&Legal

New

 

SecEdit.csv

menu&Legal

&Legal

New

 

TagLinker.csv

menu&Legal

&Legal

New

 

TrainEdit.csv

menu&Legal

&Legal

New

 

BatchMngr.csv

msg418

Cannot update the Phase parameter as it has only Read access.

New

 

msg419

The value entered is invalid Enum value.

New

 

AdminWeb.csv

HtmlTitle

AVEVA™ Batch Management History Server Administration

Modified

Old Value: AVEVA Batch Management History Server Administration

HtmlHANavHeader

AVEVA<span>™</span> Batch Management History Administration

Modified

Old Value: AVEVA Batch Management History Administration

HtmlIBHisServerAdminError

AVEVA<span>™</span> Batch Management History Server Administration Error

Modified

Old Value: AVEVA Batch Management History Server Administration Error

HtmlCannotDisplayIBHisSerAdminPage

The AVEVA<span>™</span> Batch Management History Server Administration web page cannot be displayed

Modified

Old Value: The AVEVA Batch Management History Server Administration web page cannot be displayed

HtmlIBHisSerAdminErrMsg

AVEVA<span>™</span> Batch Management History Server Administration - Error Message

Modified

Old Value: AVEVA Batch Management History Server Administration - Error Message

HtmlIBHisSerAdminLogin

AVEVA<span>™</span> Batch Management History Server Administration Login

Modified

Old Value: AVEVA Batch Management History Server Administration Login

HtmlAppTitle

AVEVA<span>™</span> Batch Management History Database Administration

Modified

Old Value: AVEVA Batch Management History Database Administration

ReportWeb.csv

HtmlTitle

AVEVA™ Batch Management Reports Administration

Modified

Old Value: AVEVA Batch Management Reports Administration

HtmlInBatchReportsTitle

AVEVA™ Batch Management Reports

Modified

Old Value: AVEVA Batch Management Reports

HtmlReportWebLogin

AVEVA<span>™</span> Batch Management Reports Administration Login

Modified

Old Value: AVEVA Batch Management Reports Administration Login

HtmlAppTitle

AVEVA<span>™</span> Batch Management Reports Administration

Modified

Old Value: AVEVA Batch Management Reports Administration

HtmlInBatchReportsAppTitle

AVEVA<span>™</span> Batch Management Reports

Modified

Old Value: AVEVA Batch Management Reports

 

© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.   |   Contact Us