Downloads

TI500 OI Server 1.2

Operations Integration Core 1.2 must be installed prior to installing this OI Server.

No UDP support (See Readme for Details).

Supports the Control Technology Inc.

  • CTI2500 (replacing the TI500's series)

Supports the controllers

  • TI545
  • TI565
  • TI575

Supports Serial and Ethernet connectivity

MES 2014 R2

New functionality includes

  • Writing of utilization reason changes can be enabled/disabled.
  • Utilization changes are performed without response through the Microsoft Message Queue.
  • Raw reason codes can be exported and imported for templates and instances. This allows raw reason codes to be transferred to other UCOs (for example, in other galaxies). It also allows a raw reason code XML import file to be created either manually or programmatically outside of ArchestrA to facilitate entry and management of a site's raw reason codes.

ABCIP OI Server 1.2

OS and Product Compatibility: Refer to Operations Integration Core.

Hardware Compatibility:

  • ControlLogix (L5x/L6x: up to Firmware 20 | L7x/L8x: up to Firmware 28)
  • GuardLogix (L6xS: up to Firmware 20 | L7xS: up to Firmware 27)
  • CompactLogix (Lxx: up to Firmware 20 | LxxERM: up to Firmware 28)
  • FlexLogix (Lxx: up to Firmware 16)
  • SoftLogix (Lx: up to Firmware 23)
  • MicroLogix (1100: up to Firmware 15 | 1200/1500: up to Firmware 14)
  • PLC-5
  • SLC500

Protocol Compatibility:

  • Ethernet
  • ControlNet thru Bridge
  • DeviceNet thru Bridge
  • Data Highway Plus (DH+) thru Bridge
  • Data Highway 485 (DH485) thru Bridge

BACnet BACLITE OI Server 1.2

Operations Integration Core 1.2 must be installed prior to installing this OI Server.

Controllers that support the BACnet protocol

Note: Change of Value (COV) is not supported.

CODESYS OI Server 1.2

Operations Integration Core 1.2 must be installed prior to installing this OI Server.

Codesys based protocols based on CODESYS version 2.x, 3.x.

The following were qualified internally, but the driver can still work with suppliers that use the CODESYS.

Bosch Rexroth

  • L40 and L65

CODESYS

  • SP WIN V3.5.1 Control
  • SP PLCWinNT V2.4.4.0
  • EATON
  • XC-CPU202 CODESYS V3.5

Schneider Electric

  • 241/M251

WAGO

  • Wago CPU 750-841

MELSEC OI Server 1.2

Operations Integration Core 1.2 must be installed prior to installing this OI Server.

The following Mitsubishi Controller families are supported:

  • MELSEC-Q
  • MELSEC-QnA
  • MELSEC-L

NOT SUPPORTED WITH THIS VERSION

  • MELSEC-iQ-R
  • MELSEC-iQ-F
  • MELSEC-F
  • MELSEC-QS/WS

TWINCAT OI Server 1.2

Operations Integration Core 1.2 must be installed prior to installing this OI Server.

The OI Server uses the ADS Library for communication and should support any TCP/IP Ethernet Beckhoff device compatible with the ADS Library version you install.

The following devices were used in the conformance tests:

ADS Library: TC1000:TC3
Beckhoff TwinCAT PLC/IO on Windows XP/7/8
CX1000

ADPRO OI Server 1.2

Operations Integration Core 1.2 must be installed prior to installing this OI Server.

Supports Automation Direct Productivity Series Controllers 2000 & 3000

DOMORE OI Server 1.2

Operations Integration Core 1.2 must be installed prior to installing this OI Server.

Supports Automation Direct Controllers Do-More H2 Series